Produkty dla hma81gs6djr8n xn (1)

Kontroler czujnika ANATOM78S..EEX w ATEX - AWAX 26XXL EEX i EEX3

Kontroler czujnika ANATOM78S..EEX w ATEX - AWAX 26XXL EEX i EEX3

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X