Produkty dla instrumenty (54)

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

Dual independent process input meters. o A math function can be performed on both signals. o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card. o Intuitive and easy programming (high flexibility) o Variable intensity display o 16 points scaling for linearisation o Programmable function keys/user inputs Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:DISP-PAXDP Type (-):Dual process input meter Input range (-):2 x 20 mA (-26 to +26 mA) / 2 x 10 VDC (-13 to +13 VDC) Sensor excitation (-):18 VDC ± 20 % @ 70 mA max. per input channel Display (-):5 digits (14.2 mm) Accuracy (% F.S.*):0.1 A/D converter (-):16 bits Converter rate (-):Up to 20 readings /s Service temperature range (°C):0...+50 Storage temperature range (°C):-40...+60 Power supply (-):85...250 VAC, 50/60 Hz (21 VA) IP rating (-):IP54
Miernik Nachylenia 2-Aksowy

Miernik Nachylenia 2-Aksowy

Beschreibung ENTWICKELT, UM RAUEN BETRIEBSBEDINGUNGEN STANDZUHALTEN Diese zweiachsigen Neigungsmesser sind für die Messung sehr kleiner Änderungen von der vertikalen Ebene aus konzipiert, entweder am Boden oder in Strukturen. Sie weisen eine hohe Auflösung und eine geringe thermische Drift auf. Ihr mechanischer Aufbau und ein verbesserter interner Überspannungsschutz machen sie besonders nützlich für die permanente Überwachung von Strukturen im Freien, die verschiedenen Einflüssen wie Belastungen und Fundamentsetzungen ausgesetzt sind. ANWENDUNGSBEREICHE - Offshore-Windturbinen-Fundamente - Brücken und Pfeiler - Historische Gebäude - Prüfung der strukturellen Belastung - Roll- und Neigungsmessung von Schiffen und Pontons - Kranroll- und Neigungsmessung - Strukturelle Gesundheitsüberwachung
Statyczne falowniki

Statyczne falowniki

De vraag naar snelheidsregeling heeft een hoge vlucht genomen met de komst van IGBT's en krachtige microprocessoren. Tegenwoordig is er geen verschil meer tussen DC en AC. 99% van de nieuwe installaties wordt uitgerust met AC-oplossingen met variabele snelheid. In ons assortiment hebben wij zowel gelijkstroom- als statische frequentieregelaars. Kenmerken van een statische frequentieregelaar: OPEN LOOP REGELING - Een- en driefasige voeding tussen 200 en 480V - Digitale omvormer - Alleen 1 of 2Q oplossing - Remmen mogelijk via chopper en weerstand - Vermogen van 0,37kW tot 22kW - IP20 bescherming - Modulaire aandrijving - Wij hebben een voorraad tot 22kW in één en drie fase REGELING MET GESLOTEN LUS - Een- en driefasige voeding tussen 200 en 500V -Digitale aandrijving Alleen -1 of 2Q oplossing -Remmen mogelijk via chopper en weerstand -Vermogen van 1,3kW tot 900kW -IP00/IP20/IP54 bescherming -Modulaire aandrijving We hebben een voorraad tot 160kW in driefase 400V
STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a static wire rope or rope fiber. o Easy and fast mounting Wide range of cable diameters from 3 up to 90 mm (0.11 to 3.5") o Material stainless steel (5560S) anodised aluminium alloy (5562S) Reference:5560S-5562S Protection class:IP67 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

Universal panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:INDI-PAXS DISP-PAXx
RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

The WIT24REHS, WIT24REHA and WIT24REHR are handheld indicators for sensors equipped with a radio transmitter. WIT24REHS 1 WIT24REHA up to 12 WIT24REHR displays all transmitters within its range (roaming) leather carry case with clear viewing window and shoulder strap (CASEPSD) Reference:WI-T24RE-Hx Frequency:2.4 GHz Licence:exemption Range:up to 800 m open field Antenna:integrated High resolution:7 digits
ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

Large panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o 5 digits of 38 mm height o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, fieldbus capabilities Reference:INDI-MAXS DISP-MAX HOUSE-MAX:Housing HOUSE-MAX-IP:Housing with protection class IP64
TENSIOMETRY LINIOWE - Tensiometry

TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a running cable or running rope. o Custommade design according to your needs type of rope (steel, synthetic, optical fiber, umbilical) capacity rope diameter (from 6 up to 115 mm) maximum winding speed accuracy Material load pin stainless steel other nickelplated steel or stainless steel (option) o Complete range of CE certified electronics and load limitation devices available Reference:5570-5575 Protection class:IP65 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

Panel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurements o Dual line display 6 digits (18 mm) and 9 digits (8.9 mm) o Tricolour display o Universal power supply (AC/DC) o Up to 160 measurements per second o Builtin USB programming port unit configuration Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485 or fieldbus capabilities NEMA 4X / IP67 (transparent cover Option "COVER PAX") Desktop or industrial steel housing DIN rail adaptor Reference:INDI-PAXS2 DISP-PAXx2
NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

Measurement transmitter designed to convert any notnormalised DC voltage or current signal into a normalised signal while providing galvanic insulation. o Voltage or current input o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply o Selection of input and output ranges by jumpers behind the front plate o Wide range of power supplies o Rail DIN mounting Compliant with EMC EN 500822 Reference:CONV-UI Weight:130 g Type (-):Signal converter Accuracy (% F.S.*):<= ± 0.2 % Bandwidth (Hz):0...1 Service temperature range (°C):-10...+60 Storage temperature range (°C):-30...+80 Power supply (-):20...270 VAC / 20...300 VDC Output tension (V):0...10 V (load resistance > 1 kohm) Output current (mA):0...20 mA, 4...20 mA (load resistance < 750 ohms) IP rating (-):IP20
STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

Load pins with standard dimensions. o CE certified for hoisting applications o Sturdy design Easy to install o Complete range of CE certified electronics and load limiters Reference:5300 Material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

Standard reference force transducers specially designed according to the ISO 376 standard (classes 1, 0,5 and 00). o Wide range of capacities o Tension and / or compression (universal) o Compact design Complete range of load accessories Reference:2712-ISO Overload protection:see drawing table Material:anodised aluminium alloy Cable length:3 m (other lengths available on request)
NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

Universal tension and compression load cells for industrial force measurement. Flat design o High stiffness and fatigue resistant o Highly resistant to transverse forces Complete range of mounting accessories available Material stainless steel (2960)**, anodised aluminium alloy (2962), alloy steel (2965) Reference:2960-2962-2965 Protection class:IP66 Cable length:see drawing table - CL (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

Universal nonrotating torque meters combining accuracy and sturdiness. o Easy to install, compact design Also available as standard reference torque meters Reference:6100-6105 Protection class:IP65 Material:stainless steel (6100), nickel-plated steel (6105) Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

Tension link load cells specially adapted for standard shackles. o Sturdy design Reference:5200-5205 Cable length:see drawing table - CL (other lengths available on request) Material:stainless steel (5200), nickel-plated steel (5205) Combined error (non-linearity + hysteresis) (% F.S.*):< ± 0.5 Repeatability error (% F.S.*):< ± 0.25 Creep error over 30 min. (% F.S.*):< ± 0.2 Zero shift after loading (% F.S.*):< ± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< ± 0.1 Zero balance (mV/V):± 0.02 Input resistance (ohm(s)):352 ± 2 Output resistance (ohm(s)):352 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):150 Breaking load (% F.S.*):> 300
CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

Low cost load cells specially designed to measure the tension force on hoisting ropes. o CE certified for hoisting applications o Easy installation directly without dismantling on the hoisting rope o Wide range of measured loads on cable (from 0.25 up to 24 t) and suitable cables (available diameters from 6 up to 46 mm) o Material 5500 stainless steel 5505 nickelplated steel Sturdy design o Reliable and economical solution o Complete range of "CE" certified electronics and load limiters available Reference:5500-5505 Protection class:IP65 Cable length:see drawing table - CL (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):>300 Permissible dynamic loading (% F.S.*):70
WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Our model 5000 is designed to measure a force or constraint, without any change to the mechanical structure, simply by replacing the clevis pin with our custommade load pin. Sturdy design o Easy to install o Complete range of CE certified electronics, load limiters and displays available for hoisting applications and lifts Reference:5000 Material:stainless steel Protection class:IP65 (up to IP68: see options) Cable length:6 m (other lengths available on request)
HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Load measuring shackles designed to measure tension force. o CE certified for hoisting applications o Sturdy design Easy to install Complete range of CE certified electronics and load limiters Reference:5000M Load pin material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

Design for underwater applications. o Custommade dimensioning o Sturdy design Easy to install Reference:5050 Material:stainless steel Protection class:IP68 Depth:up to -7500 m / -24 606 ft (750 bars / 11 000 psi) - deeper on request Cable length:6 m (other lengths available on request)
HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

Load cell combining high accuracy and resistance in harsh environment. Complies with OIML / R 60 up to 3000 d for scales in class III according to EN 45501 Standardised dimensions Whole range of mounting kits available Reference:2000S Material:stainless steel Protection class:IP67 (welded sealing) Cable length:3 m (other lengths available on request)
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, high rotating speed, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Maintenance free o Round or square shafts (see drawing) o Measurement range up to 100 N·m o Max. rotating speed Square shaft 5 000 rpm Round shaft 10 000 rpm o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62300 Cable length:5 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.5 Repeatability error (% F.S.*):<± 0.05 Rotational signal uniformity (% F.S.*):<± 0.5 Compensated temperature range (°C):+15...+35 Service temperature range (°C):-30 ... +85 Storage temperature range (°C):-30 ... +85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< 0.1 Zero signal (V):5 Safe load limit (% F.S.*):130 Power supply (-):5...28 VDC Consumption (max.) (mA):37...45 Nominal sensitivity (V):± 4 Start-up current (mA):< 100 IP rating (-):IP50
MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

Nonrotating torque meters with hexagonal head. Cable output with radial connector (see drawing) Mechanical fastening by collar (see drawing) Reference:6500B Wide range of capacities:from 2 to 1000 N·m Protection class:IP54 Material:stainless steel Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10 Zero shift after loading (% F.S.*):<± 0.025
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, lowcost, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Cost effective solution o Measurement range up to 500 N·m o Rotating speed up to 5000 rpm o Round or square shafts (see drawing) o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62100-62200 Cable length:5 m (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

Nonrotating torque meters designed to be placed between ratchet and wrench. Easy to install (standardised wrenches) o Compact design Reference:6305 Protection class:IP54 Material:alloy steel Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3 Static lateral force limit (% F.S.*):10
MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

Universal nonrotating torque meters combining accuracy and sturdiness. Easy to install, compact design Also available as standard reference torque meters Reference:6200-6205 Protection class:see drawing table (IP) Materials:stainless steel (6200), nickel-plated steel (6205) Cable length:3 m (other lengths available on request) Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):130 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, noncontact rotary torque sensors with flanges or PTO shaft. o Bidirectional o Measurement range up to 5 kN·m o Rotating speed up to 3600 rpm o Integrated signal conditioning o Analogue output signal (see Wiring table) Torque limit 5000 N·m Reference:67000 Cable length:5 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.5 Repeatability error (% F.S.*):<± 0.05 Rotational signal uniformity (% F.S.*):<± 0.5 Compensated temperature range (°C):+15...+35 Service temperature range (°C):-40 ... +85 Storage temperature range (°C):-40 ... +85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< 0.5 Temperature coefficient of zero signal (% F.S.*/10°C):< 0.5 Zero signal (V):5 Power supply (-):9...28 VDC Consumption (max.) (mA):100 Nominal sensitivity (V):± 4 Start-up current (mA):< 150 IP rating (-):IP50
OTWÓR PRZELOTOWY (ANULARNY) CZUJNIKI O DUŻEJ NOŚNOŚCI - Czujniki

OTWÓR PRZELOTOWY (ANULARNY) CZUJNIKI O DUŻEJ NOŚNOŚCI - Czujniki

Annular compression load cells. o Low profile for highcapacity load cells Sturdy design Reference:5190-5195 Material:stainless steel (5190) or nickel-plated steel (5195) Protection class:IP65 Cable length:see drawing table - CL (other lengths available on request) Repeatability error (% F.S.*):<± 0.25 Creep error over 30 min. (% F.S.*):<± 0.3 Zero shift after loading (% F.S.*):<± 0.5 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.2 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.2 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):700 ± 2 Output resistance (ohm(s)):700 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):150 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Static lateral force limit (% F.S.*):25
MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

Nonrotating torque meters with hexagonal head. Compact design, easy to install Material stainless steel (6500 / 6500A) anodised aluminium alloy (6502 / 6502A) Reference:6500-6502 6500A-6502A 6500-6502:cable output with radial cable gland 6500A-6502A:cable output with axial cable gland 6500(A)-6502(A):mechanical fastening with threaded holes (see drawing) Protection class:IP54 Cable length:see drawing table - CL (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10
Akcelerometr 1-osiowy - IAC-I

Akcelerometr 1-osiowy - IAC-I

Beschreibung Industrieller Beschleunigungssensor (4-20 mA) Die RECOVIB® Industriebeschleunigungssensoren schließen die Lücke zwischen der Leistung von Laborbeschleunigungssensoren (die oft teuer, zerbrechlich und schutzlos sind) und der Robustheit von Industriebeschleunigungssensoren (die manchmal billiger, aber oft laut und ungenau sind). Unsere Beschleunigungssensoren können in industriellen Umgebungen zur Überwachung von Maschinen oder Anlagen eingesetzt werden. Die RECOVIB® Beschleunigungssensoren sind von bewährter Konstruktion und die meisten der verfügbaren Modelle werden in einer Vielzahl von Bereichen eingesetzt, wie z.B. Werkzeugmaschinen, Präzisionsbearbeitung und Onshore- und Offshore-Windenergie in der Überwachung oder aktiven Schwingungstechnik EIGENSCHAFTEN 1,2,3 Achsen Geeignet für den direkten Anschluss an gängige Steuerungs- und Messgeräte, z.B. SPS oder Schalttafelzähler Integrierte 4..
BEZPRZEWODOWE HAKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

BEZPRZEWODOWE HAKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Wireless loadmeasuring shackles designed to measure tension force. o Sturdy design Sleep mode, remote wakeup mode, remote control of batteries o Not appropriate for overload protection Reference:5000M-WI Protection calss:IP65 Load pin material:stainless steel Frequencies:from 2.4000 to 2.4835 GHz Power:10 mW licence:exempted Range:500 m open field (antenna integrated)