Produkty dla instrumenty (48)

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

Dual independent process input meters. o A math function can be performed on both signals. o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card. o Intuitive and easy programming (high flexibility) o Variable intensity display o 16 points scaling for linearisation o Programmable function keys/user inputs Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:DISP-PAXDP Type (-):Dual process input meter Input range (-):2 x 20 mA (-26 to +26 mA) / 2 x 10 VDC (-13 to +13 VDC) Sensor excitation (-):18 VDC ± 20 % @ 70 mA max. per input channel Display (-):5 digits (14.2 mm) Accuracy (% F.S.*):0.1 A/D converter (-):16 bits Converter rate (-):Up to 20 readings /s Service temperature range (°C):0...+50 Storage temperature range (°C):-40...+60 Power supply (-):85...250 VAC, 50/60 Hz (21 VA) IP rating (-):IP54
STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a static wire rope or rope fiber. o Easy and fast mounting Wide range of cable diameters from 3 up to 90 mm (0.11 to 3.5") o Material stainless steel (5560S) anodised aluminium alloy (5562S) Reference:5560S-5562S Protection class:IP67 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

Universal panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:INDI-PAXS DISP-PAXx
RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

The WIT24REHS, WIT24REHA and WIT24REHR are handheld indicators for sensors equipped with a radio transmitter. WIT24REHS 1 WIT24REHA up to 12 WIT24REHR displays all transmitters within its range (roaming) leather carry case with clear viewing window and shoulder strap (CASEPSD) Reference:WI-T24RE-Hx Frequency:2.4 GHz Licence:exemption Range:up to 800 m open field Antenna:integrated High resolution:7 digits
ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

Large panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o 5 digits of 38 mm height o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, fieldbus capabilities Reference:INDI-MAXS DISP-MAX HOUSE-MAX:Housing HOUSE-MAX-IP:Housing with protection class IP64
TENSIOMETRY LINIOWE - Tensiometry

TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a running cable or running rope. o Custommade design according to your needs type of rope (steel, synthetic, optical fiber, umbilical) capacity rope diameter (from 6 up to 115 mm) maximum winding speed accuracy Material load pin stainless steel other nickelplated steel or stainless steel (option) o Complete range of CE certified electronics and load limitation devices available Reference:5570-5575 Protection class:IP65 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

Panel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurements o Dual line display 6 digits (18 mm) and 9 digits (8.9 mm) o Tricolour display o Universal power supply (AC/DC) o Up to 160 measurements per second o Builtin USB programming port unit configuration Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485 or fieldbus capabilities NEMA 4X / IP67 (transparent cover Option "COVER PAX") Desktop or industrial steel housing DIN rail adaptor Reference:INDI-PAXS2 DISP-PAXx2
NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

Measurement transmitter designed to convert any notnormalised DC voltage or current signal into a normalised signal while providing galvanic insulation. o Voltage or current input o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply o Selection of input and output ranges by jumpers behind the front plate o Wide range of power supplies o Rail DIN mounting Compliant with EMC EN 500822 Reference:CONV-UI Weight:130 g Type (-):Signal converter Accuracy (% F.S.*):<= ± 0.2 % Bandwidth (Hz):0...1 Service temperature range (°C):-10...+60 Storage temperature range (°C):-30...+80 Power supply (-):20...270 VAC / 20...300 VDC Output tension (V):0...10 V (load resistance > 1 kohm) Output current (mA):0...20 mA, 4...20 mA (load resistance < 750 ohms) IP rating (-):IP20
STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

Load pins with standard dimensions. o CE certified for hoisting applications o Sturdy design Easy to install o Complete range of CE certified electronics and load limiters Reference:5300 Material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

Standard reference force transducers specially designed according to the ISO 376 standard (classes 1, 0,5 and 00). o Wide range of capacities o Tension and / or compression (universal) o Compact design Complete range of load accessories Reference:2712-ISO Overload protection:see drawing table Material:anodised aluminium alloy Cable length:3 m (other lengths available on request)
NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

Universal tension and compression load cells for industrial force measurement. Flat design o High stiffness and fatigue resistant o Highly resistant to transverse forces Complete range of mounting accessories available Material stainless steel (2960)**, anodised aluminium alloy (2962), alloy steel (2965) Reference:2960-2962-2965 Protection class:IP66 Cable length:see drawing table - CL (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

Universal nonrotating torque meters combining accuracy and sturdiness. o Easy to install, compact design Also available as standard reference torque meters Reference:6100-6105 Protection class:IP65 Material:stainless steel (6100), nickel-plated steel (6105) Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

Tension link load cells specially adapted for standard shackles. o Sturdy design Reference:5200-5205 Cable length:see drawing table - CL (other lengths available on request) Material:stainless steel (5200), nickel-plated steel (5205) Combined error (non-linearity + hysteresis) (% F.S.*):< ± 0.5 Repeatability error (% F.S.*):< ± 0.25 Creep error over 30 min. (% F.S.*):< ± 0.2 Zero shift after loading (% F.S.*):< ± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< ± 0.1 Zero balance (mV/V):± 0.02 Input resistance (ohm(s)):352 ± 2 Output resistance (ohm(s)):352 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):150 Breaking load (% F.S.*):> 300
CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

Low cost load cells specially designed to measure the tension force on hoisting ropes. o CE certified for hoisting applications o Easy installation directly without dismantling on the hoisting rope o Wide range of measured loads on cable (from 0.25 up to 24 t) and suitable cables (available diameters from 6 up to 46 mm) o Material 5500 stainless steel 5505 nickelplated steel Sturdy design o Reliable and economical solution o Complete range of "CE" certified electronics and load limiters available Reference:5500-5505 Protection class:IP65 Cable length:see drawing table - CL (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):>300 Permissible dynamic loading (% F.S.*):70
WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Our model 5000 is designed to measure a force or constraint, without any change to the mechanical structure, simply by replacing the clevis pin with our custommade load pin. Sturdy design o Easy to install o Complete range of CE certified electronics, load limiters and displays available for hoisting applications and lifts Reference:5000 Material:stainless steel Protection class:IP65 (up to IP68: see options) Cable length:6 m (other lengths available on request)
HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Load measuring shackles designed to measure tension force. o CE certified for hoisting applications o Sturdy design Easy to install Complete range of CE certified electronics and load limiters Reference:5000M Load pin material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

Design for underwater applications. o Custommade dimensioning o Sturdy design Easy to install Reference:5050 Material:stainless steel Protection class:IP68 Depth:up to -7500 m / -24 606 ft (750 bars / 11 000 psi) - deeper on request Cable length:6 m (other lengths available on request)
HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

Load cell combining high accuracy and resistance in harsh environment. Complies with OIML / R 60 up to 3000 d for scales in class III according to EN 45501 Standardised dimensions Whole range of mounting kits available Reference:2000S Material:stainless steel Protection class:IP67 (welded sealing) Cable length:3 m (other lengths available on request)
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, high rotating speed, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Maintenance free o Round or square shafts (see drawing) o Measurement range up to 100 N·m o Max. rotating speed Square shaft 5 000 rpm Round shaft 10 000 rpm o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62300 Cable length:5 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.5 Repeatability error (% F.S.*):<± 0.05 Rotational signal uniformity (% F.S.*):<± 0.5 Compensated temperature range (°C):+15...+35 Service temperature range (°C):-30 ... +85 Storage temperature range (°C):-30 ... +85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< 0.1 Zero signal (V):5 Safe load limit (% F.S.*):130 Power supply (-):5...28 VDC Consumption (max.) (mA):37...45 Nominal sensitivity (V):± 4 Start-up current (mA):< 100 IP rating (-):IP50
MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

Nonrotating torque meters with hexagonal head. Cable output with radial connector (see drawing) Mechanical fastening by collar (see drawing) Reference:6500B Wide range of capacities:from 2 to 1000 N·m Protection class:IP54 Material:stainless steel Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10 Zero shift after loading (% F.S.*):<± 0.025
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, lowcost, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Cost effective solution o Measurement range up to 500 N·m o Rotating speed up to 5000 rpm o Round or square shafts (see drawing) o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62100-62200 Cable length:5 m (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

Nonrotating torque meters designed to be placed between ratchet and wrench. Easy to install (standardised wrenches) o Compact design Reference:6305 Protection class:IP54 Material:alloy steel Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3 Static lateral force limit (% F.S.*):10
MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

Universal nonrotating torque meters combining accuracy and sturdiness. Easy to install, compact design Also available as standard reference torque meters Reference:6200-6205 Protection class:see drawing table (IP) Materials:stainless steel (6200), nickel-plated steel (6205) Cable length:3 m (other lengths available on request) Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):130 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, noncontact rotary torque sensors with flanges or PTO shaft. o Bidirectional o Measurement range up to 5 kN·m o Rotating speed up to 3600 rpm o Integrated signal conditioning o Analogue output signal (see Wiring table) Torque limit 5000 N·m Reference:67000 Cable length:5 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.5 Repeatability error (% F.S.*):<± 0.05 Rotational signal uniformity (% F.S.*):<± 0.5 Compensated temperature range (°C):+15...+35 Service temperature range (°C):-40 ... +85 Storage temperature range (°C):-40 ... +85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< 0.5 Temperature coefficient of zero signal (% F.S.*/10°C):< 0.5 Zero signal (V):5 Power supply (-):9...28 VDC Consumption (max.) (mA):100 Nominal sensitivity (V):± 4 Start-up current (mA):< 150 IP rating (-):IP50
OTWÓR PRZELOTOWY (ANULARNY) CZUJNIKI O DUŻEJ NOŚNOŚCI - Czujniki

OTWÓR PRZELOTOWY (ANULARNY) CZUJNIKI O DUŻEJ NOŚNOŚCI - Czujniki

Annular compression load cells. o Low profile for highcapacity load cells Sturdy design Reference:5190-5195 Material:stainless steel (5190) or nickel-plated steel (5195) Protection class:IP65 Cable length:see drawing table - CL (other lengths available on request) Repeatability error (% F.S.*):<± 0.25 Creep error over 30 min. (% F.S.*):<± 0.3 Zero shift after loading (% F.S.*):<± 0.5 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.2 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.2 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):700 ± 2 Output resistance (ohm(s)):700 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):150 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Static lateral force limit (% F.S.*):25
MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

Nonrotating torque meters with hexagonal head. Compact design, easy to install Material stainless steel (6500 / 6500A) anodised aluminium alloy (6502 / 6502A) Reference:6500-6502 6500A-6502A 6500-6502:cable output with radial cable gland 6500A-6502A:cable output with axial cable gland 6500(A)-6502(A):mechanical fastening with threaded holes (see drawing) Protection class:IP54 Cable length:see drawing table - CL (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10
BEZPRZEWODOWE HAKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

BEZPRZEWODOWE HAKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Wireless loadmeasuring shackles designed to measure tension force. o Sturdy design Sleep mode, remote wakeup mode, remote control of batteries o Not appropriate for overload protection Reference:5000M-WI Protection calss:IP65 Load pin material:stainless steel Frequencies:from 2.4000 to 2.4835 GHz Power:10 mW licence:exempted Range:500 m open field (antenna integrated)
CZUJNIKI OBCIĄŻENIA NA ROZCIĄGANIE I ŚCISKANIE - Czujniki obciążenia

CZUJNIKI OBCIĄŻENIA NA ROZCIĄGANIE I ŚCISKANIE - Czujniki obciążenia

Highaccuracy universal load cells, easy to install. Overload protection in tension and compression (only for 2712A and 2712C) o Compact design Also available as standard reference load cells according to ISO 376 (classes "1", ''0,5'' and ''00'' see specific data sheet 2712ISO) Reference:2712 Wide range of capacities:from 100 N to 10 kN Protection class:IP54 / IP65 (see drawing) Cable length:3 m (other lengths available on request)
WYSOKOPOJEMNE STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ - Transduktory siły referencyjnej

WYSOKOPOJEMNE STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ - Transduktory siły referencyjnej

Standard reference force transducers specially designed according to ISO 376 standard (classes 1, 0,5 and 00). o Wide range of capacities (up to 50 MN) o Complete range of load accessories Reference:3115-ISO Protection class:IP65 Material:alloy steel (stainless steel available on request) Cable length:see drawing table - CL (other lengths available on request)
CZUJNIKI NAPIĘCIA I ŚCISKANIA (BARDZO WYSOKIE POJEMNOŚCI) - Czujniki obciążenia

CZUJNIKI NAPIĘCIA I ŚCISKANIA (BARDZO WYSOKIE POJEMNOŚCI) - Czujniki obciążenia

Accuracy universal load cells, easy to install. Reference:5100-5105 Wide range of capacities:10 kN (1 t) up to 50 MN (5.000 t) Protection class:IP66 Material:stainless steel (5100)**, nickel-plated steel (5105) Cable length:see drawing table - CL (other lengths available on request)