Produkty dla instrumenty (99)

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

PODWÓJNE WYŚWIETLACZE WEJŚCIOWE - Instrumentacja

Dual independent process input meters. o A math function can be performed on both signals. o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card. o Intuitive and easy programming (high flexibility) o Variable intensity display o 16 points scaling for linearisation o Programmable function keys/user inputs Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:DISP-PAXDP Type (-):Dual process input meter Input range (-):2 x 20 mA (-26 to +26 mA) / 2 x 10 VDC (-13 to +13 VDC) Sensor excitation (-):18 VDC ± 20 % @ 70 mA max. per input channel Display (-):5 digits (14.2 mm) Accuracy (% F.S.*):0.1 A/D converter (-):16 bits Converter rate (-):Up to 20 readings /s Service temperature range (°C):0...+50 Storage temperature range (°C):-40...+60 Power supply (-):85...250 VAC, 50/60 Hz (21 VA) IP rating (-):IP54
Miernik Nachylenia 2-Aksowy

Miernik Nachylenia 2-Aksowy

Beschreibung ENTWICKELT, UM RAUEN BETRIEBSBEDINGUNGEN STANDZUHALTEN Diese zweiachsigen Neigungsmesser sind für die Messung sehr kleiner Änderungen von der vertikalen Ebene aus konzipiert, entweder am Boden oder in Strukturen. Sie weisen eine hohe Auflösung und eine geringe thermische Drift auf. Ihr mechanischer Aufbau und ein verbesserter interner Überspannungsschutz machen sie besonders nützlich für die permanente Überwachung von Strukturen im Freien, die verschiedenen Einflüssen wie Belastungen und Fundamentsetzungen ausgesetzt sind. ANWENDUNGSBEREICHE - Offshore-Windturbinen-Fundamente - Brücken und Pfeiler - Historische Gebäude - Prüfung der strukturellen Belastung - Roll- und Neigungsmessung von Schiffen und Pontons - Kranroll- und Neigungsmessung - Strukturelle Gesundheitsüberwachung
Statyczne falowniki

Statyczne falowniki

De vraag naar snelheidsregeling heeft een hoge vlucht genomen met de komst van IGBT's en krachtige microprocessoren. Tegenwoordig is er geen verschil meer tussen DC en AC. 99% van de nieuwe installaties wordt uitgerust met AC-oplossingen met variabele snelheid. In ons assortiment hebben wij zowel gelijkstroom- als statische frequentieregelaars. Kenmerken van een statische frequentieregelaar: OPEN LOOP REGELING - Een- en driefasige voeding tussen 200 en 480V - Digitale omvormer - Alleen 1 of 2Q oplossing - Remmen mogelijk via chopper en weerstand - Vermogen van 0,37kW tot 22kW - IP20 bescherming - Modulaire aandrijving - Wij hebben een voorraad tot 22kW in één en drie fase REGELING MET GESLOTEN LUS - Een- en driefasige voeding tussen 200 en 500V -Digitale aandrijving Alleen -1 of 2Q oplossing -Remmen mogelijk via chopper en weerstand -Vermogen van 1,3kW tot 900kW -IP00/IP20/IP54 bescherming -Modulaire aandrijving We hebben een voorraad tot 160kW in driefase 400V
Kontrola szczelności zbiorników podziemnych - Spokój i pewność dla operatora

Kontrola szczelności zbiorników podziemnych - Spokój i pewność dla operatora

Dichtheidscontroles op ondergrondse opslagtanks en andere luchtdichte compartimenten Met onze krachtige en veelzijdige ultrasone dectectors kunt u heel gemakkelijk op dichtheid controleren. Het is de enige manier om te garanderen dat ondergrondse opslagtanks luchtdicht zijn. Maar dit is niet de enige toepassing waarvoor ultrasone dichtheidscontroles gebruikt kunnen worden. Er bestaan wel meer dingen die luchtdicht moeten zijn. De motor of cabine van een auto bijvoorbeeld, grote scheepvaartcontainers of de lagerbehuizing in een fabriek die papier produceert. Wanneer de dichtheid niet langer gegarandeerd is, kunnen er vervelende dingen gebeuren. Er kunnen bijvoorbeeld dingen lekken of binnensijpelen, iets wat altijd vermeden moet worden.
AutoMapper do soczewek recepturowych - Inspekcja RX

AutoMapper do soczewek recepturowych - Inspekcja RX

The Dual LensMapper, integrated in this unit, gives a mapping of the prescription lens (freeform or conventional) and calculates FOA optical power at the reference points (FV, NV). For the freeforms, it compares the expected design to the real lens and displays an error map. A Go/NoGo decision is made, based on the error map and the list of criteria defined by the lab. Because the A&R AutoMapper is task specific, and the system has a small footprint, you can easily integrate it into the lab, either directly after the surfacing or in the final control (also suitable for checking the cut lenses). The AutoMapper is an excellent investment for a modern lab with a rapid payback! 100 % production control just after surfacing --> direct feedback on production* control of the cut lens - in case of remote edging Non contact measurement Correction of eventual R/L inversion Integrated Dual LensMapper : measurement of free form and conventional progressive lenses Control of power, cyl. Diameter (via shape measurement):44 to 80 mm NB : grippers also designed to handle cut lenses NB:grippers also designed to handle cut lenses Max. power for positive axis:+10.00D Min. power for negative axis:-10.00D Cylinder:0 to +4.00D DPT:0.04 D CYL:PRISM PRISM:0.03cm/m + 1° Contactless thickness meausrement:0.04mm 150 jobs/hour:L = 191cm L = 191cm:W = 140 cm W = 140 cm:H = 192 cm (without Laminar flow box) H = 192 cm (without Laminar flow box):Laminar flow box Laminar flow box:Table for rejected lenses Table for rejected lenses:Our company Our company:Products Products:Services Services:References/Experiences References/Experiences:News News:Contact Contact:test
Przenośny rejestrator przepływu - IFQ LOGGER

Przenośny rejestrator przepływu - IFQ LOGGER

The IFQ LOGGER is a portable converter and logger for Flow-Tronic flow sensors. It disposes of one RS485 digital serial communication port with specific communication protocols for RAVEN-EYE or BELUGA flow sensors and one 4-20 mA input for external level. The IFQ LOGGER combines high performance with low power requirements. The unit needs 12 VDC nominal power supply either provided from an optional battery pack or solar panels. The IFQ LOGGER keeps the same easy configuration enhanced by the IFQ MONITOR and stays in line with the flexible and modular architecture launched by the RAVEN-EYE. All flow sensors are field interchangeable. A dry contact output is available for users needing an output for samplers or any other instrument. KEY FEATURES: 1 x RS485 digital sensor interface for velocity (RAVEN-EYE or BELUGA) 1 x 4-20 mA analog input for level sensor 7 position sealed membrane keypad 2 Gb memory (SD card) Power supply : 9 to 18 VDC Enclosure: PPC (IP67)
ECMF8 - Kontroler do destratyfikacji z opcjonalną/zintegrowaną bramą internetową

ECMF8 - Kontroler do destratyfikacji z opcjonalną/zintegrowaną bramą internetową

This control unit has two 0-10 Volt outputs to regulate the EC fans. Via the 2 tacho inputs you can directly monitor the status of the fans and their speed, if tacho signals are available on the fans. HVAC sensors or potentiometers can be connected to the unit, via Modbus RTU communication or 2 analogue inputs. The built-in 24 VDC power supply can feed the external sensors or potentiometers. The controller itself needs a supply voltage between 85 - 305 VAC. Application specific firmware is needed for the unit to function. This firmware can be downloaded via Senteraweb, our online HVAC portal, where we already made a limited number of specific firmware version available, used in typical HVAC applications like destratification. The only thing that needs to be done is to select the appropriate functionality on the solution page of our website and download the firmware. No additional programming is required. TCMF8 is also available - for AC fan speed control.
Instrumentowana Skrzynka na Monety - HF 53

Instrumentowana Skrzynka na Monety - HF 53

La boîte à coin instrumentée appelée HF 53 est en réalité une boîte à coin standard de marque CROSBY sur laquelle nous avons remplacé l’axe standard par un axe dynamométrique muni d’un dispositif anti-rotation. Tout comme l’axe dynamométrique, l’effort engendré par la boîte à coin sur l’axe produit un signal de mesure qui est proportionnel à l’effort. Pour une question d’immunité électromagnétique, le signal est directement converti en fréquence dans le corps de l’axe. Ce signal fréquence généré par le tourillon est relié par un câble faradisé au moniteur électronique HF 80 qui en assure la gestion complète. Les paramètres de gestion sont protégés par un code d’accès.
STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

STATYCZNE TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a static wire rope or rope fiber. o Easy and fast mounting Wide range of cable diameters from 3 up to 90 mm (0.11 to 3.5") o Material stainless steel (5560S) anodised aluminium alloy (5562S) Reference:5560S-5562S Protection class:IP67 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

ANALOGOWE MIERNIKI WEJŚCIOWE PANELU - Instrumentacja

Universal panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, USB or fieldbus capabilities NEMA 4X / IP67 (transparent protection cover Option "COVER PAX") Desktop or industrial steel housing Rail DIN adaptor Reference:INDI-PAXS DISP-PAXx
RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

RĘCZNE ODBIORNIKI RADIOWE Z WYŚWIETLACZEM - Instrumentacja

The WIT24REHS, WIT24REHA and WIT24REHR are handheld indicators for sensors equipped with a radio transmitter. WIT24REHS 1 WIT24REHA up to 12 WIT24REHR displays all transmitters within its range (roaming) leather carry case with clear viewing window and shoulder strap (CASEPSD) Reference:WI-T24RE-Hx Frequency:2.4 GHz Licence:exemption Range:up to 800 m open field Antenna:integrated High resolution:7 digits
ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

ANALOGOWE WEJŚCIOWE DUŻE MIERNIKI PANELOWE - Instrumentacja

Large panel meters to be used with transducers and process signals o Strain gauge, process, voltage and current inputs o 5 digits of 38 mm height o Intuitive and easy programming (high flexibility) o 16 points scaling for linearisation o Programmable function keys/user inputs o Variable intensity display Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485, fieldbus capabilities Reference:INDI-MAXS DISP-MAX HOUSE-MAX:Housing HOUSE-MAX-IP:Housing with protection class IP64
TENSIOMETRY LINIOWE - Tensiometry

TENSIOMETRY LINIOWE - Tensiometry

Load cells specially designed to measure the tension force applied to a running cable or running rope. o Custommade design according to your needs type of rope (steel, synthetic, optical fiber, umbilical) capacity rope diameter (from 6 up to 115 mm) maximum winding speed accuracy Material load pin stainless steel other nickelplated steel or stainless steel (option) o Complete range of CE certified electronics and load limitation devices available Reference:5570-5575 Protection class:IP65 Cable length:6 m (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):70
ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

ANALOGOWE WSKAŹNIKI WEJŚCIOWE Z PODWÓJNYM WYŚWIETLACZEM - Instrumentacja

Panel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurements o Dual line display 6 digits (18 mm) and 9 digits (8.9 mm) o Tricolour display o Universal power supply (AC/DC) o Up to 160 measurements per second o Builtin USB programming port unit configuration Analogue output 4 (0)...20 mA or 0...10 V 2 or 4 setpoints with relay outputs RS232, RS485 or fieldbus capabilities NEMA 4X / IP67 (transparent cover Option "COVER PAX") Desktop or industrial steel housing DIN rail adaptor Reference:INDI-PAXS2 DISP-PAXx2
NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

NADAJNIK POMIAROWY DLA SYGNAŁÓW NAPIĘCIA I PRĄDU DC - Instrumentacja

Measurement transmitter designed to convert any notnormalised DC voltage or current signal into a normalised signal while providing galvanic insulation. o Voltage or current input o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply o Selection of input and output ranges by jumpers behind the front plate o Wide range of power supplies o Rail DIN mounting Compliant with EMC EN 500822 Reference:CONV-UI Weight:130 g Type (-):Signal converter Accuracy (% F.S.*):<= ± 0.2 % Bandwidth (Hz):0...1 Service temperature range (°C):-10...+60 Storage temperature range (°C):-30...+80 Power supply (-):20...270 VAC / 20...300 VDC Output tension (V):0...10 V (load resistance > 1 kohm) Output current (mA):0...20 mA, 4...20 mA (load resistance < 750 ohms) IP rating (-):IP20
STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

STANDARDOWE WTYKI OBLOADOWE - Ochrona przed przeciążeniem dźwigów

Load pins with standard dimensions. o CE certified for hoisting applications o Sturdy design Easy to install o Complete range of CE certified electronics and load limiters Reference:5300 Material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

STANDARDOWE TRANSDUKTORY SIŁY REFERENCYJNEJ W ROZCIĄGANIU I ŚCISKANIU - Transduktory siły referencyjnej

Standard reference force transducers specially designed according to the ISO 376 standard (classes 1, 0,5 and 00). o Wide range of capacities o Tension and / or compression (universal) o Compact design Complete range of load accessories Reference:2712-ISO Overload protection:see drawing table Material:anodised aluminium alloy Cable length:3 m (other lengths available on request)
NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

NISKOPROFILOWE (PANCAKE) CZUJNIKI OBLOADU - Czujniki obciążenia

Universal tension and compression load cells for industrial force measurement. Flat design o High stiffness and fatigue resistant o Highly resistant to transverse forces Complete range of mounting accessories available Material stainless steel (2960)**, anodised aluminium alloy (2962), alloy steel (2965) Reference:2960-2962-2965 Protection class:IP66 Cable length:see drawing table - CL (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI (WYSOKIE KAPACITETY) - Transduktory momentu

Universal nonrotating torque meters combining accuracy and sturdiness. o Easy to install, compact design Also available as standard reference torque meters Reference:6100-6105 Protection class:IP65 Material:stainless steel (6100), nickel-plated steel (6105) Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

CZUJNIKI ŁADUNKU LINKI NAPIĘCIA - Czujniki ładunku

Tension link load cells specially adapted for standard shackles. o Sturdy design Reference:5200-5205 Cable length:see drawing table - CL (other lengths available on request) Material:stainless steel (5200), nickel-plated steel (5205) Combined error (non-linearity + hysteresis) (% F.S.*):< ± 0.5 Repeatability error (% F.S.*):< ± 0.25 Creep error over 30 min. (% F.S.*):< ± 0.2 Zero shift after loading (% F.S.*):< ± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< ± 0.1 Zero balance (mV/V):± 0.02 Input resistance (ohm(s)):352 ± 2 Output resistance (ohm(s)):352 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):150 Breaking load (% F.S.*):> 300
CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

CZUJNIKI OBLOADU LINY - Ochrona przed przeciążeniem dźwigów

Low cost load cells specially designed to measure the tension force on hoisting ropes. o CE certified for hoisting applications o Easy installation directly without dismantling on the hoisting rope o Wide range of measured loads on cable (from 0.25 up to 24 t) and suitable cables (available diameters from 6 up to 46 mm) o Material 5500 stainless steel 5505 nickelplated steel Sturdy design o Reliable and economical solution o Complete range of "CE" certified electronics and load limiters available Reference:5500-5505 Protection class:IP65 Cable length:see drawing table - CL (other lengths available on request) Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.1 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):>300 Permissible dynamic loading (% F.S.*):70
WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

WYKONANE NA ZAMÓWIENIE PINY ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Our model 5000 is designed to measure a force or constraint, without any change to the mechanical structure, simply by replacing the clevis pin with our custommade load pin. Sturdy design o Easy to install o Complete range of CE certified electronics, load limiters and displays available for hoisting applications and lifts Reference:5000 Material:stainless steel Protection class:IP65 (up to IP68: see options) Cable length:6 m (other lengths available on request)
HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

HACZYKI ŁADUNKOWE - Ochrona przed przeciążeniem dźwigów

Load measuring shackles designed to measure tension force. o CE certified for hoisting applications o Sturdy design Easy to install Complete range of CE certified electronics and load limiters Reference:5000M Load pin material:stainless steel Protection class:IP65 Cable length:6 m (other lengths available on request)
PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

PINSY ŁADUNKOWE PODWODNE / ZANURZONE - Ochrona przed przeciążeniem dźwigów

Design for underwater applications. o Custommade dimensioning o Sturdy design Easy to install Reference:5050 Material:stainless steel Protection class:IP68 Depth:up to -7500 m / -24 606 ft (750 bars / 11 000 psi) - deeper on request Cable length:6 m (other lengths available on request)
HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

HERMETYCZNIE ZAMKNIĘTA BELKA ZGINAJĄCA CZUJNIK OBLOADU - Czujniki wagowe

Load cell combining high accuracy and resistance in harsh environment. Complies with OIML / R 60 up to 3000 d for scales in class III according to EN 45501 Standardised dimensions Whole range of mounting kits available Reference:2000S Material:stainless steel Protection class:IP67 (welded sealing) Cable length:3 m (other lengths available on request)
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, high rotating speed, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Maintenance free o Round or square shafts (see drawing) o Measurement range up to 100 N·m o Max. rotating speed Square shaft 5 000 rpm Round shaft 10 000 rpm o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62300 Cable length:5 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.5 Repeatability error (% F.S.*):<± 0.05 Rotational signal uniformity (% F.S.*):<± 0.5 Compensated temperature range (°C):+15...+35 Service temperature range (°C):-30 ... +85 Storage temperature range (°C):-30 ... +85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< 0.1 Temperature coefficient of zero signal (% F.S.*/10°C):< 0.1 Zero signal (V):5 Safe load limit (% F.S.*):130 Power supply (-):5...28 VDC Consumption (max.) (mA):37...45 Nominal sensitivity (V):± 4 Start-up current (mA):< 100 IP rating (-):IP50
MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

MIERZNIKI MOMENTU REAKCJI - Transduktory momentu

Nonrotating torque meters with hexagonal head. Cable output with radial connector (see drawing) Mechanical fastening by collar (see drawing) Reference:6500B Wide range of capacities:from 2 to 1000 N·m Protection class:IP54 Material:stainless steel Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10 Zero shift after loading (% F.S.*):<± 0.025
BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

BEZKONTAKTOWE OBROTOWE CZUJNIKI MOMENTU - Przetworniki momentu

General purpose, lowcost, noncontact rotary torque sensors with square or round shaft. o Bidirectional o Cost effective solution o Measurement range up to 500 N·m o Rotating speed up to 5000 rpm o Round or square shafts (see drawing) o Integrated signal conditioning o Analogue output signal (see Wiring table) Reference:62100-62200 Cable length:5 m (other lengths available on request)
MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI DLA KLUCZY RATCHET - Przetworniki momentu

Nonrotating torque meters designed to be placed between ratchet and wrench. Easy to install (standardised wrenches) o Compact design Reference:6305 Protection class:IP54 Material:alloy steel Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3 Static lateral force limit (% F.S.*):10
MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

MIERZNIKI MOMENTU REAKCJI - Przetworniki momentu

Universal nonrotating torque meters combining accuracy and sturdiness. Easy to install, compact design Also available as standard reference torque meters Reference:6200-6205 Protection class:see drawing table (IP) Materials:stainless steel (6200), nickel-plated steel (6205) Cable length:3 m (other lengths available on request) Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):130 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3