Produkty dla instrumenty (195)

Cairsens® SO₂ - Miniaturowe rozwiązanie do ciągłego monitorowania SO2 w czasie rzeczywistym

Cairsens® SO₂ - Miniaturowe rozwiązanie do ciągłego monitorowania SO2 w czasie rzeczywistym

The Cairsens© SO2 sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:SO2 Measuring Range (ppm):0 – 1 Certified Detection Limit (ppm):0.05 Resolution (ppm):0.001 Operating Temperature (°C):-20 to +50
ALERT WYCIEKU 75 - Monitor pyłu/wycieku filtra elektrodynamicznego

ALERT WYCIEKU 75 - Monitor pyłu/wycieku filtra elektrodynamicznego

Standalone TÜV approved filter dust leak monitor suited to the monitoring of filter emissions (0100%) after bag houses, cartridge filters, cyclones, etc. • reliable monitoring of leaking and broken bags in dust collectors • external display • inbuilt sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtimes and filter costs
Graphite 52M - Podgrzewany detektor jonizacji płomieniowej (FID) analizator

Graphite 52M - Podgrzewany detektor jonizacji płomieniowej (FID) analizator

One of the sole QAL 1 certified FID analyzers on the market, also available in a transportable version for the measurement of THC or simultaneous THC, nmHC & CH4. Utilizes Flame Ionization Detection (FID), the most sensitive and widely used technology for the measurement of Total hydrocarbons (THC) / Nonmethanic Hydrocarbons (NmHC) / Methane (CH4) • ideal for wet and corrosive process conditions • high accuracy, sensitivity and stability • real time calibration graph • complies with EN 12619 & EN 13526 standards for emissions monitoring • complies with CFR 40 1065 (US EPA) for engine emission testing of hydrocarbons
MP101M + OPM - Automatyczny i działający w czasie rzeczywistym monitor cząstek zawieszonych

MP101M + OPM - Automatyczny i działający w czasie rzeczywistym monitor cząstek zawieszonych

MP101M beta gauge monitor with its optional optical particulate monitor. Measured parameter:PM10, PM2.5, PM1, TSP Technology:Beta Ray Attenuation US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 10 000 μg/m3 Measurement units:µg/m3 Lower Detectable Limit (2σ):0.5 μg/m3 (24h average) Sample flow rate:1 m³/h Temperature range:+5°C to 40°C
LabAnalyzer 254 - Szybkie oznaczanie rtęci w zastosowaniach analitycznych

LabAnalyzer 254 - Szybkie oznaczanie rtęci w zastosowaniach analitycznych

The LabAnalyzer is the perfect solution for quantitative determination of mercury in aqueous samples and sample digests in the laboratory. Measuring principle:cold vapor atomic absorption (CVAAS) at 253.7 nm; Peak method UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method :Reference beam method Optical cell:Fused silica (Suprasil), l: approx. 230mm, heated approx. 45° Sample volume:2 – 10 ml
Cairsens® NH₃ - Miniaturowe rozwiązanie do ciągłego monitorowania NH3 w czasie rzeczywistym

Cairsens® NH₃ - Miniaturowe rozwiązanie do ciągłego monitorowania NH3 w czasie rzeczywistym

The Cairsens© NH3 micro-sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:NH3 Measuring Range (ppm):0 – 25 Certified Detection Limit (ppm):0.5 Resolution (ppm):0.001 Operating Temperature (°C):-20 to 40
M-Sens 2 - Online pomiar wilgotności resztkowej

M-Sens 2 - Online pomiar wilgotności resztkowej

Microwave sensor for continuous moisture measurement in dry bulk solids and installation on conveyor belts, screw feeder or hoppers. Microwave based sensor for high resolution and accuracy. • highly resistant to abrasion • integrated temperature reading • flow detection function • moisture ranges 0 65 % • measurement accuracy 0.1 % • ATEXcertified
LAS 5000XD - In-Situ Laserowy Analizator Gazu

LAS 5000XD - In-Situ Laserowy Analizator Gazu

LAS 5000XD uses Tunable Diode Laser Spectroscopy (TDLS) and comes in various models for measuring parameters such as NH3 + H2O, HF, CO + CO2, O2, HCl + H2O, etc. It combines robustness, fast response time (1 s) and high accuracy measurement in harsh environments. NH3 + H2O:0–10 ppm / 0–5000 ppm + 0–5% / 0–40% HF:0–3 ppm / 0–500 ppm CO + H2O:0–50 ppm / 0–1% + 0–5% / 0–40% CO + CO2:0-1% / 0-100% + 0-1% / 0-100% Lower Detection Limit:< 1% of FS Response Time (0–90%) – Short:1 s Lack of fit/Linearity :≤ ±1%
Cairsens® CO - Miniaturowe rozwiązanie do ciągłego monitorowania CO w czasie rzeczywistym

Cairsens® CO - Miniaturowe rozwiązanie do ciągłego monitorowania CO w czasie rzeczywistym

The Cairsens© CO sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:CO Measuring Range (ppm):0 – 20 Certified Detection Limit (ppm):0.05 Resolution (ppm):0.001 Operating Temperature (°C):-20 to +50
VIEW 820 - Elektrodynamiczny monitor pyłu

VIEW 820 - Elektrodynamiczny monitor pyłu

Certified multisensor dust monitor – category 1 under ATEX / IECEx – for indicative emissions trending and measurement in hazardous zones and in dry processes with elevated pressures. Advanced probe electrification featuring long term data logging for process trend analysis and reporting. • reliable measurement of leaking and broken bags in dust collectors • sensor configured remotely via controller • automatic sensor drift checks • automatic probe check for improved data integrity • reduces filter maintenance intervals, process downtimes and filter costs
DensFlow HP - Pomiar przepływu w wysokociśnieniowym transporcie gęstej fazy

DensFlow HP - Pomiar przepływu w wysokociśnieniowym transporcie gęstej fazy

Continuous flow measurement of powder or granules in high pressure densephase conveying. Designed to measure solid flows during pneumatic dense phase transport. The sensor measures density and speed. • pressureresistant up to 64 bar • maintenancefree • contactless • ATEX category 3 approved
MIR 9000ASD - Analizator Absorpcji UV SO2

MIR 9000ASD - Analizator Absorpcji UV SO2

Eco-designed, ultra-compact, smart & connected continuous gas analyzer, for emission or process gas monitoring. Perfectly suited to control SO2 removal efficiency in processes using Flue-gas desulfurization FGD / DeSOx systems. Measurement range:0-100 / 0-1000 mg/m3 user programmable; 0-35 / 0-1500 ppm user programmable Minimum detectable limit (2σ):0.2 ppm Noise (σ):0.1 ppm Response time (0-90 %):5 – 40 sec (programmable) Zero drift:< 1 ppm / 7 days Span drift:< 1% / 7 days Linearity:± 1 %
AMESA-M - System pułapki na sorbent rtęci

AMESA-M - System pułapki na sorbent rtęci

Mercury emission monitoring by sorbent traps is a good and practical alternative to conventional Hg CEMS. Measuring range: (total mercury) :0.01 – 1000μg/m3 Sampling period::from 15 minutes up to 4 weeks Flue gas temperature::< 200˚C with heated probe; > 200˚C on request Max. dust concentration in flue gas::20 mg/m3 Operating temperature::+5 to +40˚C (optional with air conditioner: -20 to + 55˚C)
FlowJam Plus - Monitor przepływu materiału z wykrywaniem zatorów

FlowJam Plus - Monitor przepływu materiału z wykrywaniem zatorów

Material flow monitoring with Flow/No Flow information plus additional “Detection of blockage” or “Material flow interruption” function (Jam/NoJam) • contactless operation using microwaves • particularly reliable device due to microwaves passing through material accumulations • Measurement from outside for all nonmetallic tank walls, housings, hose lines or pipelines • usable in ATEX zones and high operating temperatures
VOC72M - Analizator lotnych związków organicznych

VOC72M - Analizator lotnych związków organicznych

The VOC72M’s metrology, in accordance with EN 14662-3 (2005) & EN 15267-1 (2009) standard for benzene measurement, is based on gas chromatography (GC) coupled with a photo-ionization detector (PID). Measured parameter:VOC (Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1,3 Butadiene) Technology:Gas Chromatography US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 1000 µg/m3 Measurement units:ppb, ppm, µg/m3 (user-selectable) Noise (σ):≤ 0.025 µg/m3 at 0.5 µg/m3 benzene Lower Detectable Limit (2σ):≤ 0.05 µg/m3 benzene Zero drift:≤ 4% / 15 days Span drift:< 1% / 7 days Sample flow rate:50 ml/min Temperature range:0°C to +30°C Data storage:1 year
Kirscher broszka i końcówka broszki

Kirscher broszka i końcówka broszki

Broches pour ostéosynthèse standard et sur mesure vendus stériles et non stériles. Conception, fabrication et négoce d’implants orthopédiques mais aussi de divers matériels chirurgicaux. Pour mieux répondre aux besoins de notre clientèle, nous étudions toute demande concernant des produits spécifiques.
Postel śruby ze stali nierdzewnej

Postel śruby ze stali nierdzewnej

Clous pour ostéosynthèse standard et sur mesure vendus stériles et non stériles. Conception, fabrication et négoce d’implants orthopédiques mais aussi de divers matériels chirurgicaux. Pour mieux répondre aux besoins de notre clientèle, nous étudions toute demande concernant des produits spécifiques.
QAL 991 - Certyfikowane Pomiar Pyłu

QAL 991 - Certyfikowane Pomiar Pyłu

Kontinuierliche Überwachung von Staubemissionen nach Gewebe- oder Patronenfiltern. Messbare Parameter:Staub Technologie:ElectroDynamic Messbereich:0-1000 mg/m³ Kamindurchmesser:bis zu 8 m Rauchgastemperatur:bis zu 500 °C Gewebefilter:Ja Kartuschenfilter:Ja Koaleszenzabscheider:Ja Zyklone:Ja
STACK 990 - Zatwierdzony elektrodynamicznie CEM cząsteczkowy

STACK 990 - Zatwierdzony elektrodynamicznie CEM cząsteczkowy

TÜV approved particulate monitor providing high quality emission measurement for low dust concentrations from dry industrial processes including baghouses and cartridge filters. • robust design unaffected by product buildup on the sensor rod • no additional services such as air purge required, providing lower cost of ownership • simple maintenance • drift checks and contamination checks
Cairsens® H₂S / CH₄S - Miniaturowe rozwiązanie do ciągłego monitorowania H2S / CH4S w czasie rzeczywistym

Cairsens® H₂S / CH₄S - Miniaturowe rozwiązanie do ciągłego monitorowania H2S / CH4S w czasie rzeczywistym

The Cairsens© H₂S / CH₄S sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:H2S / CH4S Measuring Range (ppm):0 – 1 | 0 – 20 | 0 – 200 Certified Detection Limit (ppm):0.01 | 0.03 | 0.2 Resolution (ppm):0.001 Operating Temperature (°C):-20 to +40
Cairnet - Autonomiczne sieci mini-stacji opartych na czujnikach

Cairnet - Autonomiczne sieci mini-stacji opartych na czujnikach

Cairnet® device is a real-time standalone and networkable air-monitoring station including up to six Cairsens® microsensors. It is powered by solar panels and offers cellular communication. Power supply:8 to 30 V DC / 2.5 A or battery (included) Battery included:3.7 V – 22 Ah, Li-Ion rechargeable on 18VDC / 2A or via solar pannels (option) Solar Panels Kit (option):27 Watts. Mounting bracket included Pollutant:NO2 Pollutant:O3 / NO2 Pollutant:SO2 Pollutant:H2S / CH4S Pollutant:NH3 Pollutant:nmVOC Pollutant:PM10/PM2.5/PM1
AF22e Rozcieńczenie - Analizator Dwutlenku Siarki

AF22e Rozcieńczenie - Analizator Dwutlenku Siarki

QAL1 zertifiziertes und US-EPA zugelassenes UV-Fluoreszenz-Gasüberwachungssystem für die Überwachung von SO2 im Bereich von 0-10 ppm oder 0-1 ppm SO2:0-300 / 6000 ppb H2S:0-150 ppb Probenahme-Technologie:Verdünnung Probentransfer:nicht beheiztes Polyrohr Rückspülfunktion:Ja Bereichsinjektion:Ja
MIR IS - In-situ ściśle sprzężony analizator wielogazowy

MIR IS - In-situ ściśle sprzężony analizator wielogazowy

A complete “all in one" compact system, for multigas measurements, based on the fieldproven MIR 9000 analyzer and onboard SEC sampling system. Fast & simultaneous measurement of up to 10 gases among HCl, NO, NO2 (NOx), SO2, CO, CO2, HC, CH4 (TOC), HF, N2O, O2, at the sampling location. • integrated sample drying & system conditioning, no sample line necessary • designed for measuring wet & corrosive samples • complete CEMS in one cabinet combines infrared analyzer, sample conditioning • highly accurate, excellent calibration stability with automatic optional check
MIR 9000 P - Przenośny analizator wielogazowy NDIR-GFC

MIR 9000 P - Przenośny analizator wielogazowy NDIR-GFC

The MIR 9000 P measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the nondispersive infrared method (NDIRGFC) with gas filter correlation. O2 is measured by a builtin SRM paramagnetic sensor. • operational at any time due to standby mode • remote access to full operation • quick installation • onsite preparation of report elements • time saving all along emission testing process
LCPD BOX - Podgrzewany system pobierania próbek

LCPD BOX - Podgrzewany system pobierania próbek

Extraktives und beheiztes Probenahmesystem aus Edelstahl mit integriertem beheizten Partikelfilter. Probenahmesystem:Heiße nasse Extraktion (Nassbasisanalyse) Sondenrohr:Edelstahl Probenahmeleitung:beheizt
AutoCal - Automatyczna Jednostka Kalibracyjna dla UT-3000

AutoCal - Automatyczna Jednostka Kalibracyjna dla UT-3000

Dient der automatischen Kalibrierung des Mercury Ultratracers UT-3000. Reinheit des enthaltenen Hg:99,999999% Genauigkeit des T-Sensors:0,01 °C
UT-3000 NG mobilny - Mobilny analizator ultratrace rtęci dla gazu ziemnego

UT-3000 NG mobilny - Mobilny analizator ultratrace rtęci dla gazu ziemnego

Perfectly adapted to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants. Measuring principle:Amalgamation (MI GoldTrap), cold vapor atomic absorption (CVAAS) at 253.7 nm UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Measured component:Total Gaseous Mercury (TGM) Detection limit:1 pg absolutely or 0.1 ng/m³
ALERT WYCIEKU 73 - Monitor pyłu/wycieku filtra elektrodynamicznego

ALERT WYCIEKU 73 - Monitor pyłu/wycieku filtra elektrodynamicznego

Standalone filter dust leak monitor (0100%) for filter emissions monitoring after baghouses, cartridge filters, cyclones etc. where performance approvals are not required. • reliable monitoring of leaking and broken bags in dust collectors • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs
VM-3000 - Monitor Par Rtęci

VM-3000 - Monitor Par Rtęci

Der VM-3000 misst kontinuierlich die Hg-Konzentration in Luft und Gasen. Er eignet sich perfekt für die kontinuierliche Überwachung der Luftqualität, für das Umwelt-Monitoring, die Qualitätskontrolle oder die Emissionsüberwachung. Messprinzip:Kaltdampf UV-Absorption (CVAAS) bei 253,7 nm UV-Quelle:Elektrodenlose Hg-Niederdrucklampe (EDL) Stabilisierung:Referenzstrahl-Technik Optische Zelle:Quarzglas (Suprasil) Nachweisempfindlichkeit:0.1 μg/m³
MVS - System zarządzania CEMS przez multipleksowanie

MVS - System zarządzania CEMS przez multipleksowanie

MVS 2M is a multichannel system allowing to distribute two, three or four channels of fluids and signals to a gas monitoring system (GMS). Operating temperature:+5°C to +40°C Communication port:RS232/RS422, Ethernet