Produkty dla instrumenty (195)

VIEW 370 - Monitor pyłu elektrodynamiczny

VIEW 370 - Monitor pyłu elektrodynamiczny

Multisensor dust monitor designed for high quality emission measurement in industrial stacks after bag filters, cartridge filters, cyclones and process driers. Advanced probe electrification multisensor dust monitor designed for high quality emission measurement in industrial stacks where regulatory approvals are not necessary. • PRO version permits multichannel networked system for plantwide monitoring of emissions (for up to 32 sensors) • full colour, icondriven menu and display • two independent alarm set points • relative dust reading on clear scale 0100% • dust 'overrange' icon • security setting • digital signal processing • field upgradeable
MMS-NG - Automatyczne monitorowanie rtęci w gazie ziemnym

MMS-NG - Automatyczne monitorowanie rtęci w gazie ziemnym

Automatic systemdesigned for continuous mercury monitoring in natural gas even in hazardous zones (ATEX, IEC-Ex). Measuring principle:Amalgamation (MI GoldTrap), cold vapor atomic absorption (CVAAS) at 253.7 nm UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Optical cell:Fused silica (Suprasil), l: approx. 230mm, heated approx. 45° Measured component:Total Gaseous Mercury (TGM) Detection limit:1 pg absolutely or 0.1 ng/m³
AMESA-D - System długoterminowego pobierania próbek dla dioksyn i furanów

AMESA-D - System długoterminowego pobierania próbek dla dioksyn i furanów

QAL1 und MCERTs zertifiziertes Langzeitprobenahmesystem für Dioxine, Furane und PCBs. Messbereich:0.0001–10 ng I-TEQ / m³ Probenahmeintervall:6 h – 6 Wochen Rauchgastemperatur:bis 70°C ohne Kühlwasser / bis zu 400˚C mit Kühlwasser Rauchgasgeschwindigkeit:1 bis zu 30 m/s
MP101M - Ciągły, automatyczny monitor cząstek zawieszonych

MP101M - Ciągły, automatyczny monitor cząstek zawieszonych

PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 according the ISO 10473 Standard. QAL 1 certified and US EPA approved. Measured parameter:PM10, PM2.5, PM1, TSP Technology:Beta Ray Attenuation US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 10 000 μg/m3 Measurement units:µg/m3 Lower Detectable Limit (2σ):0.5 μg/m3 (24h average)
PM Cairsens® PM1, PM2.5 i PM10 - Ciągłe monitorowanie w czasie rzeczywistym PM1, PM2.5 i PM10

PM Cairsens® PM1, PM2.5 i PM10 - Ciągłe monitorowanie w czasie rzeczywistym PM1, PM2.5 i PM10

Messung von PM1- und PM10-Konzentrationen, mit erhöhter Präzision für PM2,5. Messbare Parameter:PM1, PM2.5 & PM10 Messbereich:0 – 1 000 µg/m3 Partikelgröße ø:0.3 – 10 µm Zertifizierte Nachweißgrenze:< 5 µg/m3
ZAG7001 - Generator Powietrza Zero

ZAG7001 - Generator Powietrza Zero

Null-Luft-Generator gibt kontinuierlich bis zu 20 Standardliter pro Minute (SLPM) trockene, schadstofffreie Luft ab. Standardliter pro Minute (SLPM):20 Interner Kompressor:Ja Innentrockner:Typ PSA
Cairsens® O₃ + NO₂ - Ciągłe pomiary O3 i NO2 w czasie rzeczywistym

Cairsens® O₃ + NO₂ - Ciągłe pomiary O3 i NO2 w czasie rzeczywistym

Mikro-Sensor für die präzise und zuverlässige Messung von O3 und NO2. Messbare Parameter:O3 + NO2 Messbereich (ppm):0 – 0.25 Zertifizierte Nachweisgrenze (ppm):0.02 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis 40
LEAK LOCATE 662 - Monitory wydajności filtrów

LEAK LOCATE 662 - Monitory wydajności filtrów

The LEAK LOCATE 662 is a digitally networked, multicompartment baghouse monitoring system providing remote observation of the condition of bag and cartridge filters. • reliable monitoring of leaking and broken bags in dust collectors • sensor configuration remotely via controller • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs
LGD 2M - Moduł detekcji gazu laserowego NH3 (TDLS)

LGD 2M - Moduł detekcji gazu laserowego NH3 (TDLS)

Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) Gas:NH3 Principle of detection:Tunable Diode Laser Spectrometry (TDLS) Ranges:0-100 / 0-20 ppm Precision 2σ :1.8 ppm @ 1 s; 0.8 ppm @ 10 s Response time:< 2 sec (T90) (at gas flow rate of 3 L/min) Cell temperature range:190°C Operating temperature:+15 to +50°C Communication:RS 232 Dimensions:Rack 19″ – 3U
DM 170 - Monitor emisji cząstek przez rozpraszanie światła

DM 170 - Monitor emisji cząstek przez rozpraszanie światła

The DM 170 is designed to comply with the TÜV suitability testing scheme to EN 15267 and for measuring dust concentrations in a wide range of industrial applications. Due to its wide dynamic range, the DM 170 may be used in combustion applications as well as in higher dust loading applications (such as power, cement and metals smelting, and in processes without filtration). Its simplicity and wide operating range makes it also ideally suited for process optimisation applications. • ProScatter™ backscatter sensor technology • Manual and remote Zero and Span checks available to ensure optimal instrument performance • purge flow fail sensor and optical shield options • nonintrusive system designed to operate in noncondensing stack environments • Singleside stack installation reduces contamination risk
QAL 991 - Zatwierdzony CEM cząstek QAL1

QAL 991 - Zatwierdzony CEM cząstek QAL1

Continuous emission monitor providing high quality emission measurement for low dust concentrations from dry industrial processes. Measured parameters:Dust Technology:ElectroDynamic™ Advanced Probe Electrification Measurement/Monitoring capability:0-1000 mg/m³ Stack/Duct diameter suitability:up to 8m Flue gas temperature:up to 500°C Baghouse:Yes Cartridge Filter:Yes Coalescent Filter:Yes Cyclone:Yes
VOC72e - Analizator lotnych związków organicznych

VOC72e - Analizator lotnych związków organicznych

Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3, the newest standard for benzene measurement. Measured parameter:VOC (Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1,3 Butadiene) Technology:Gas Chromatography US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 1000 µg/m3 Measurement units:ppb, ppm, µg/m3 (user-selectable) Noise (σ):≤ 0.025 µg/m3 at 0.5 µg/m3 benzene Lower Detectable Limit (2σ):≤ 0.05% µg/m3 benzene Zero drift:≤ 4% / 15 days Span drift:< 1% / 7 days
Anemometr ultradźwiękowy dla Cairnet - Czujnik prędkości i kierunku wiatru

Anemometr ultradźwiękowy dla Cairnet - Czujnik prędkości i kierunku wiatru

Das Gerät misst die Windgeschwindigkeit und Windrichtung und wird über ein integriertes Solarpanel mit Strom versorgt. Es verfügt über eine wiederaufladbare Lithium-Batterie. Bereich der Windgeschwindigkeit:1 – 40 m/s Auflösung der Windgeschwindigkeit:1 m/s Empfindlichkeit der Windgeschwindigkeit:0,13 m/s Bereich der Windrichtung:0 – 359° Auflösung der Windrichtung:10° Empfindlichkeit gegenüber der Windrichtung:+/- 1.5°
AMESA-B - System długoterminowego pobierania próbek dla biogennego CO2

AMESA-B - System długoterminowego pobierania próbek dla biogennego CO2

Das AMESA-B dient zur kontinuierlichen Überwachung von biogenen CO2-Emissionen. So kann der klimaneutrale Anteil am gesamten CO2-Ausstoß ermittelt werden, für den dann keine Emissionshandelszertifikate nötig sind. Entnahmekapazität:5- 50 Nml/min Probenahmezeit:mehreren Stunden bis zu 1 Monat Umgebungstemperatur Standard:+5 °C bis +38 °C Umgebungstemperaturen mit Klimagerät:>+38 °C Umgebungstemperaturen mit Heizgerät:<+5 °C
MIR 9000 - Analizator wielogazowy NDIR-GFC

MIR 9000 - Analizator wielogazowy NDIR-GFC

Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2. MultiGas NDIRGFC analyzer (NonDispersive Infrared Gas Filter Correlation) measuring up to ten gases simultaneously, including Nitrogen Oxide (NO), Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2), Carbon Monoxide (CO), even Hydrogen Chloride (HCl) and Hydrogen Fluoride (HF). • process optimization and environmental compliance • measurement of dry and corrosive samples • fast and simultaneous measurements of up to 10 gases • dry basis measurement • automatic cross interference correction
DIL-1 / MS-1 - System rozcieńczania

DIL-1 / MS-1 - System rozcieńczania

Ideal for mid-high to high concentrations, also for sampling locations in hazardous areas (ATEX). Maximum sample gas temperature:– standard probe: + 400°C; quartz probe: + 600°C Dilution rate:12/1 to 350/1 function of the type of critical orifice selected Accuracy of dilution rate:± 2 %
Cairsens® NH₃ - Ciągłe Monitorowanie w Czasie Rzeczywistym NH3

Cairsens® NH₃ - Ciągłe Monitorowanie w Czasie Rzeczywistym NH3

Spezifische Schadstoffmessung zur Überwachung von NH3. Messbare Parameter:NH3 Messbereich (ppm):0 – 25 Zertifizierte Nachweisgrenze (ppm):0.5 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis 40
Cairsens® SO₂ - Ciągły Pomiar SO₂ w Czasie Rzeczywistym

Cairsens® SO₂ - Ciągły Pomiar SO₂ w Czasie Rzeczywistym

Präzise und zuverlässige Echtzeitmessung von SO2. Messbare Parameter:SO2 Messbereich (ppm):0 – 1 Zertifizierte Nachweisgrenze (ppm):0.05 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis +50
NG Sampling System 3000 - System przygotowania próbek dla gazu ziemnego

NG Sampling System 3000 - System przygotowania próbek dla gazu ziemnego

Probenaufbereitungssystem zur Entnahme von Probengas aus einer unter Druck stehenden Erdgasquelle. Partikelfilter:1 micron Edelstahl T-Filter Maximaler Probengasdruck (Einlass):ca. 200 bar Druck am Ausgang:0.0 – 1.0 bar (typischerweise 0.28 bar)
AF22e - Analityk dwutlenku siarki serii E SO2

AF22e - Analityk dwutlenku siarki serii E SO2

UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Option: H2S / TRS monitoring. Measured parameter :SO2 Technology:UV Fluorescence US-EPA Approval / QAL 1 Certification:Yes Measurement ranges :0-1 ppm or 0-10 ppm user-defined Measurement units:ppb, ppm, µg/m3 user-defined Lower Detectable Limit (2σ):< 0.4 ppb Noise (σ):< 0.2 ppb Zero drift:< 1 ppb / 24h Span drift:< 0.5% / 7 days Linearity:± 1%
FlowJam - Ciągłe wykrywanie przepływu materiału

FlowJam - Ciągłe wykrywanie przepływu materiału

Microwave sensor for contactless monitoring of material flow and detection of material blockage. The FlowJam is a processsecure device, since the microwave technology used can penetrate material coating on the sensor and reliably detect the material movement behind it. • detection of material blockage and material standstill • insensitive against material deposits • for any line diameter • compact (no separate electronics) • with ceramic mounting, usable up to 1,000 °C
MIR 9000P - Przenośny analizator NDIR wieloskładnikowy

MIR 9000P - Przenośny analizator NDIR wieloskładnikowy

Der MIR 9000P gehört zur neuen Generation der ENVEA Gasmessgeräte, die sich durch ECO-Design und smarte Technologie auszeichnet. Er misst gleichzeitig 8 Gase – NOx, SO2, CO, CO2, CH4, N2O, O2 und Rest-H2O – und verwendet die nicht-dispersive Infrarotmethode (NDIR-GFC) mit Gasfilterkorrelation. O2 wird durch einen eingebauten paramagnetischen SRM-Sensor gemessen. Der Analysator wurde entwickelt, um die speziellen Anforderungen von Messungen vor Ort zu erfüllen und bietet eine hervorragende Mobilität, Robustheit, Genauigkeit und Konformität. All dies macht ihn zu einem einzigartigen Gasemissionsmessgerät mit hoher Produktivität und niedrigen Betriebskosten. US EPA konform:Ja Probenahme:Kalt / Trocken -Extriebe Probenahmetransfer:Nicht beheiztes Polytube / beheizte Probenahmeleitung Eingebaute O2 Option:Ja Messbarer Parameter:SO2, NO oder NOx, CO, CO2 , N2O, CH4, O2 und Rest-H2O Programmeinheiten:ppm, mg / m 3 oder% Vol.
SM-4 Mobilny - Modułowy Monitor Spalin Rtęci

SM-4 Mobilny - Modułowy Monitor Spalin Rtęci

Ideal zur Überwachung von Hg-Reduzierungssystemen an verschiedenen Messstellen. Messkomponente:Gesamtquecksilber UV-Quelle:Elektrodenlose Hg-Niederdrucklampe (EDL) Stabilisierung:Referenzstrahl-Technik Optische Zelle:Quarzglas Messbereich:0,05 μg/m³ bis 500 μg/m³ Hg Nachweisgrenze:0,0001 μg/m³ (Detektor); < 0,01 μg/m³ (System)
PicoFlow - Pomiar przepływu przy niskich stosunkach stałych/powietrza

PicoFlow - Pomiar przepływu przy niskich stosunkach stałych/powietrza

Electrodynamic flow sensor for the measurement of low flow rates from 0 to 100 kg/h. For pipe diameters up to 1 m. Ideally used in leanphase conveying. In free fall conditions with at least 2 m/s drop speed. • suitable for very low concentrations • ceramic coating prevents sensor wear
PM162M - Automatyczny sekwencyjny pobornik cząstek

PM162M - Automatyczny sekwencyjny pobornik cząstek

Automatische Probenahme von Partikeln auf Filtern mit einem TSP-, PM10-, PM2,5- oder PM1-Einlass. Messbare Parameter:Partikel Technologie:Sammler Temperaturbereich :+5 °C bis +40 °C Datenspeicher:> 6 Monate
STACK 980 - Zatwierdzony CEM cząstek

STACK 980 - Zatwierdzony CEM cząstek

Filter dust approved particulate monitoring system for low dust concentrations from dry industrial processes. Measured parameters:Dust Technology: Measurement/Monitoring capability Stack/Duct diameter suitability:up to 8m Flue gas temperature:up to 800°C Baghouse:Yes Cartridge Filter:Yes Ceramic Filter:Yes Coalescent Filter:Yes Cyclone:Yes QA checks:Yes
SM-3 - Monitor rtęci dla spalin

SM-3 - Monitor rtęci dla spalin

Messung von ionischem und gebundenem Quecksilber in Rauchgas. Thermokatalytische Behandlung des Rauchgas direkt am Kamin. Messkomponente:Gesamtquecksilber (TGM) UV-Quelle:Elektrodenlose Hg-Niederdrucklampe (EDL) Stabilisierung:Referenzstrahl-Technik Optische Zelle:Quarzglas Messbereiche:0 – 50 µg/m³; 0 – 75 µg/m³; 0 – 500 µg/m³ Nachweisgrenze:< 1 µg/m³
STACK 980 - Pomiar pyłu zgodnie z MCERTs

STACK 980 - Pomiar pyłu zgodnie z MCERTs

Filterbruchüberwachung nach MCERTs zur Messung niedriger Staubkonzentrationen nach Schlauch- oder Patronenfiltern. Zu messendes Material:Staub Technologie:ElectroDynamic Mess-/Überwachungskapazität:0 – 1000 mg/m³ Kamin-/Kanaldurchmesser:bis zu 8 m Prozesstemperatur:bis zu 800 °C Schlauchfilter :Ja Patronenfilter :Ja Keramikfilter:Ja Koaleszenzfilter:Ja Zyklon:Ja
M-Sens 3 - Niezawodne pomiary wilgotności o wysokiej rozdzielczości

M-Sens 3 - Niezawodne pomiary wilgotności o wysokiej rozdzielczości

Microwave sensor for continuous moisture measurement in dry bulk solids, with flow detection and process temperature measurement. • highly resistant to abrasion • integrated temperature reading • flow detection function • measurement accuracy 0.1 % • ATEXcertified
AF22e - Analizator Dwutlenku Siarki

AF22e - Analizator Dwutlenku Siarki

QAL1-zertifizierter Gasanalysator zur Überwachung von SO2 im Messbereich 0-10 ppm oder 0-1 ppm. Messgröße:SO2 Technologie:UV Fluoreszenz QAL 1-Zertifizierung:Ja US-EPA Zulassung:Ja Messbereiche:0-1 ppm oder 0-10 ppm benutzerdefiniert Messeinheiten:ppb, ppm, µg/m3 benutzerdefiniert Untere Nachweisgrenze (2σ):< 0.4 ppb Rauschen (σ):< 0.2 ppb