Produkty dla instrumenty (291)

STACKFLOW 400 - Zatwierdzona prędkość spalin cem

STACKFLOW 400 - Zatwierdzona prędkość spalin cem

Approved flue gas velocity CEM for stack velocity, volumetric flow and pollutant mass release calculations when linked to gas and dust CEMS. Measured parameters:Flue-gas velocity Technology:FlueSonic™ Ultrasonic Measurement/Monitoring capability:0 – 50 m/s Stack/Duct diameter suitability:up to 10 m Flue gas temperature:up to 200 °C Baghouse:Yes Cartridge Filter:Yes Coalescent Filter:Yes Cyclone:Yes Electrostatic Precipitator (ESP):Yes Wet Electrostatic Precipitator (WESP):Yes Wet Scrubber:Yes QA checks:Yes
CO12e - Analizator tlenków węgla

CO12e - Analizator tlenków węgla

Referenz-Luftqualitäts-Überwachungssystem für CO-Messungen im Bereich 0-50 ppm. Optional kann CO2 überwacht werden. Messgröße:CO Technologie:Gasfilter-Korrelation – NDIR QAL 1 Zertifizierung:Ja US-EPA Zulassung:Ja Messbereiche:0-50 ppm (0-300 ppm auf Anfrage) Messeinheiten:ppb, ppm, µg/m3 (benutzerdefiniert) Untere Nachweisgrenze (2σ):0.05 ppm Rauschen (σ):0.025 ppm
Cairsens® O₃ + NO₂ - Miniaturowe rozwiązanie do ciągłego monitorowania O3 + NO2 w czasie rzeczywistym

Cairsens® O₃ + NO₂ - Miniaturowe rozwiązanie do ciągłego monitorowania O3 + NO2 w czasie rzeczywistym

The Cairsens© O2 + NO3 sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:O3 + NO2 Measuring Range (ppm):0 – 0.25 Certified Detection Limit (ppm):0.02 Resolution (ppm):0.001 Operating Temperature (°C):-20 to 40
BERYL 92M - FTUV analizator amoniaku (NH3)

BERYL 92M - FTUV analizator amoniaku (NH3)

Ultra-fast NH3 measurement (Ultra-fast response time: < 2 seconds). Ranges:0-100 / 0-500 ppm Lower detectable limit:0.4 ppm Response time:< 2 sec (T90) Zero drift:< 2% F.S. / 24 h Span drift:2 % F.S. / 24 h Linearity :± 1 % F.S. Sample flow rate:0.1 to 5 l/min Heated block temperature :190°C Operating temperature :+5 to +45°C Communication:RS 232
DIL-1 / MS-1 - System Rozcieńczania

DIL-1 / MS-1 - System Rozcieńczania

Ideal für mittelhohe bis hohe Konzentrationen, auch in explosionsgefährdeten Bereichen und zur Verwendung mit AC32e, CO12e, AF22e, HC51M oder MIR 9000. Temperaturbereich Standard:+ 400 °C Temperaturbereich Quartzsonde:+ 600 °C Verdünnungsrate:12/1 bis 350/1 Genauigkeit der Verdünnungsrate:± 2 %
VOC72M - Analizator Lotnych Związków Organicznych

VOC72M - Analizator Lotnych Związków Organicznych

Gaschromatographie in Verbindung mit einem Photoionisationsdetektor zur Messung von organischen Verbindungen wie Benzol, Toluol, Ethylbenzol, m+p-Xylol, o-Xylol, 1-3 Butadien. Messbare Parameter:VOC (Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1,3 Butadiene) Technologie:Gaschromatographie QAL1-Zertifikat:Ja US-EPA Zulassung:Ja Messbereich:0-1000 µg/m3 Messeinheit:ppb, ppm, µg/m3 (frei wählbar) Nachweisgrenze (2σ):≤ 0.025% µg/m3 at 0.5 µg/m3 benzene Rauschen (σ):≤ 0.5%
M-Sens WR3 - Online pomiar wilgoci resztkowej

M-Sens WR3 - Online pomiar wilgoci resztkowej

Sensor for continuous moisture measurement in dry bulk solids and installation on conveyor belts, screw feeder or hoppers. Microwave based sensor for high resolution and accuracy. • highly resistant to abrasion • extended measurement range, up to 85 % moisture • high temperature version up to 190 °C • measurement accuracy 0.1 % • recording of surface moisture and capillary moisture
QAL 181 - Rozpraszanie cząstek do przodu CEM

QAL 181 - Rozpraszanie cząstek do przodu CEM

QAL1 approved ProScatter™ particulate CEM providing high quality emission measurement of low dust concentrations from dry industrial processes. Measured parameters:Dust Technology:ProScatter™ Forward Scatter Measurement/Monitoring capability:0-1000 mg/m³ Stack/Duct diameter suitability:up to 8m Flue gas temperature:up to 500°C Baghouse:Yes Cartridge Filter:Yes Ceramic Filter:Yes Coalescent Filter:Yes Cyclone:Yes Electrostatic Precipitator (ESP):Yes
DM 210 - Monitor pyłu filtra cząstek

DM 210 - Monitor pyłu filtra cząstek

Filter leak monitor suited to filter control applications after fabric dust filter type (baghouse) arrestment plant. Measured parameters:Dust Technology:Electrodynamic™ Probe Electrification Measurement/Monitoring capability:0-500 mg/m3 (Leak monitoring) Stack/Duct diameter suitability:0.5 to 8 m Flue gas temperature:250°C standard, 400°C option Baghouse:Yes Cartridge Filter:Yes Ceramic Filter:Yes Coalescent Filter:Yes Cyclone:Yes
FlowJam S - Ciągłe wykrywanie przepływu materiału z monitorowaniem trendów

FlowJam S - Ciągłe wykrywanie przepływu materiału z monitorowaniem trendów

Microwave sensor for contactless monitoring of material flows with trend monitoring. • detection of material clogging and material standstill • insensitive against material deposits • for any line diameter • compact (no separate electronics) • with ceramic mounting, usable up to 1,000 °C • usable in dust exzones
STACK 181 WS - CEM cząsteczkowy dla mokrych strumieni gazowych

STACK 181 WS - CEM cząsteczkowy dla mokrych strumieni gazowych

US EPA PS11 capable ProScatter™ particulate CEM for the extractive sampling and measurement of particulate in saturated wet gas streams. Measured parameters:Dust Technology:Extractive ProScatter™ Forward Scatter Measurement/Monitoring capability:0-500 mg/m³ Stack/Duct diameter suitability:up to 15m Flue gas temperature:up to 200°C Wet Electrostatic Precipitator (WESP):Yes Wet Scrubber:Yes QA checks:Yes
MIR 9000 CLD - Analizator IR-GFC wielogazowy

MIR 9000 CLD - Analizator IR-GFC wielogazowy

Standard Reference CLD method for low & ultra low NOx measurement, IRGFC for CO, CO2, SO2, N2O, NOx, HF, HCl, TOC and O2 in a single analyse. Fast and simultaneous measurements of up to 10 gases. • measurement of dry and corrosive samples • unheated sample line • intrinsic security with onboard residual H2O measurements • onboard oxygen measure for environmental reporting • highly accurate, excellent stability with automatic optical stability check
BERYL 92M - FTUV Analizator Amoniaku

BERYL 92M - FTUV Analizator Amoniaku

Vermeidet durch die Verwendung des UV-Bereichs für die Messung von NH3 Interferenzen mit anderen wichtigen Emissionsgasen (CO, CO2, H2O, usw..), die im UV nicht absorbieren. Messbereich:0-100 / 0-500 ppm Nachweisgrenze:0.4 ppm Reaktionszeit:< 2 sec (T90) Null-Drift:< 2% F.S. / 24 h Messbereichs-Drift:2 % F.S. / 24 h Linearität:± 1 % F.S. Ultraschnelle Reaktionszeit:< 2 Sekunden
MIR 2M - Analityk multigazowy CO, CO2 i O2

MIR 2M - Analityk multigazowy CO, CO2 i O2

Multigas-Infrarot-Analysator für Messungen niedriger CO-Konzentrationen (0-10 bis 0-50 ppm). Messbereich:CO: 10 bis 50,000 ppm, CO2: 100 bis 250,000 ppm, O2: 0 bis 25%v Reaktionszeit (0-90 %):2 sek. Temperaturbereich :+15°C bis + 40°C
QAL 360 - Testowane pomiary pyłu z technologią rozpraszania wstecz

QAL 360 - Testowane pomiary pyłu z technologią rozpraszania wstecz

QAL1 zertifizierte Emissionsmessung für Staubkonzentrationen aus industriellen Prozessen mit einem Zertifizierungsbereich von 0-7,5 mg/m³. Messbare Parameter:Staub Technologie:ProScatter Rückwärtsstreuung Messbereich:<0 – 500 mg/m³ Eignung für Durchmesser:bis zu 10 m Rauchgastemperatur:bis zu 400 °C Taschenfilter:Ja Kartuschenfilter:Ja Zyklone:Ja Elektrofilter (ESP):Ja
ProSens - Pomiar pyłu po filtrach

ProSens - Pomiar pyłu po filtrach

The ProSens has been specially developed to carry out reliable dust measurement on clean sides after filters. The measuring device provides measurement values for dust concentration, either as a trend signal or as absolute values (after calibration) for emission measurement. • continuous, precise and reliable dust quantity measurement (mg/m³) • dust measurement possible in large channel diameters • output of dust concentration as absolute value • ATEXcertified • measurement of dust concentration at high temperatures or harsh environments • trend signal or absolute value
Cairsens® nmVOC - Ciągłe Monitorowanie w Czasie Rzeczywistym nmVOC

Cairsens® nmVOC - Ciągłe Monitorowanie w Czasie Rzeczywistym nmVOC

Mikro-Sensor für die präzise und zuverlässige Messung von nmVOC. Messbarer Parameter:nmVOC Messbereich:0 – 2 | 0 – 16 Zertifizierte Nachweisgrenze (ppm):0.2 | 0.5 Auflösung (ppm):0.001
MGC101 - Kalibrator wielogazowy dla analizatorów gazów w powietrzu otoczenia

MGC101 - Kalibrator wielogazowy dla analizatorów gazów w powietrzu otoczenia

The MGC101 system automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases.
SM-4 - Monitor całkowitych emisji rtęci

SM-4 - Monitor całkowitych emisji rtęci

QAL 1 certified for continuous, accurate and reliable measurement of total mercury emissions, even in very low concentrations and within complex matrices (SO2, NOx, HCl, etc.). Measuring principle:Thermocatalytic reduction at stack, Amalgamation (MI GoldTrap), cold vapor atomic absorption (CVAAS) Measured component:Total mercury UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Measuring ranges:0.05 μg/m³ – 500 μg/m³ Hg (up to 1000 µg/m³ as an option) Detection limit:0.0001 μg/m³ (Detector); < 0.01 μg/m³ (System)
O342e - Analityk ozonu serii E O3

O342e - Analityk ozonu serii E O3

LED based, UV photometric ozone analyzer providing accurate, stable and repeatable O3 measurements in the range of 0-500 ppb or 0-10 ppm. Measured parameter:O₃ Technology:UV photometry & LED US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:0-1 ppm / 0-10 ppm Measurement units:ppb, ppm, µg/m3 (user-selectable) Lower Detectable Limit (2σ):0.2 ppb Noise (σ):0.1 ppb Zero drift:< 0.5 ppb / 24h, < 1 ppb / 7 days Span drift:< 0.5% / 24h, < 1% / 7days Linearity:± 1% FS Sample flow rate:1L/min
CalSet - Ręczny zestaw kalibracyjny do UT-3000

CalSet - Ręczny zestaw kalibracyjny do UT-3000

This accessory is meant for manually calibrating the UT-3000 Mercury Ultratracer. Purity of contained Hg:99,999999% Accuracy of T-sensor:0,01 °C Power supply:230 VAC / 50 Hz (110 VAC / 60 Hz option) Power consumption:30 VA
QAL 182 WS - CEM cząstek dla mokrych strumieni gazowych

QAL 182 WS - CEM cząstek dla mokrych strumieni gazowych

Continuous particulate monitoring for saturated wet stack applications typically found after wet scrubbers, wet electrostatic precipitators and wet flue gas desulphurisation plants. Measured parameters:Dust Technology:Extractive ProScatter™ Forward Scatter Measurement/Monitoring capability:0-500 mg/m³ Stack/Duct diameter suitability:up to 15m Flue gas temperature:up to 200°C Wet Electrostatic Precipitator (WESP):Yes Wet Scrubber :Yes
ALERT WYCIEKU 80 - Monitor pyłu/wycieku filtra elektrodynamicznego

ALERT WYCIEKU 80 - Monitor pyłu/wycieku filtra elektrodynamicznego

Standalone TÜV approved filter dust monitor suited to the measurement of filter emissions after bag houses, cartridge filters, cyclones etc. • reliable measurement of leaking and broken bags in dust collectors • external display and keyboard • inbuilt sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs
MP101M + OPM - Automatyczne Monitorowanie Cząstek Zawieszonych w Czasie Rzeczywistym

MP101M + OPM - Automatyczne Monitorowanie Cząstek Zawieszonych w Czasie Rzeczywistym

Beta Messgerät mit optionalem OPM (Optischer Partikelsensor). Präzises Messgerät zur Überwachung der Beta-Dämpfung von PM10, PM2,5, PM1. Optische Echtzeit-Anzeige der Massenkonzentration unter Verwendung eines unabhängigen Einlasses. Messbare Parameter:PM10, PM2.5, PM1, TSP Technologie:Beta-Strahlen-Dämpfung QAL1 Zertifizierung:Ja US-EPA Zulassung:Ja Messbereich:bis zu 10 000 μg/m3 Messbare Einheit:µg/m3
HC51M - Analizator FID dla Całkowitych Węglowodorów

HC51M - Analizator FID dla Całkowitych Węglowodorów

Messung von Kohlenwasserstoffen (THC, CH4, nmHC) in der Umgebungsluft unter Verwendung eines Flammenionisationsdetektors (FID). Messbare Parameter:THC / nmHC Technologie:Flammenionisationsdetektor (FID) Messbereiche:0-10 ppm / 0-1000 ppm Messeinheiten:ppb, ppm, µg/m3 (frei wählbar) Nachweisgrenze (2σ):< 0.05 ppm Rauschen (σ):0.025 ppm
Cairsens® nmVOC - Miniaturowe rozwiązanie do ciągłego monitorowania nmVOC w czasie rzeczywistym

Cairsens® nmVOC - Miniaturowe rozwiązanie do ciągłego monitorowania nmVOC w czasie rzeczywistym

The Cairsens© sensor allows specific pollutant measurement comparable to reference methods. Measured Parameter:nmVOC Measuring Range (ppm):0 – 2 | 0 – 16 Certified Detection Limit (ppm):0.2 | 0.5 Resolution (ppm):0.001 Operating Temperature (°C):-20 to 50
MMS - Automatyczne monitorowanie rtęci w powietrzu i gazach

MMS - Automatyczne monitorowanie rtęci w powietrzu i gazach

The MMS basically comprises a multiplexer-valve unit and a highly accurate and selective mercury detector (VM-3000 Vapor Monitor) for measurements in air and other gases. Measuring principle:cold vapor atomic absorption (CVAAS) at 253.7 nm UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Optical cell:Fused silica (Suprasil), l: approx. 230mm, heated approx. 45° Measured component :Total Gaseous Mercury (TGM) Measuring ranges (Standard version):1 – 100; 1- 1000; 1 – 2000 µg / m³
ProGap 2.0 - Monitorowanie poziomu punktowego

ProGap 2.0 - Monitorowanie poziomu punktowego

Microwave barrier for contactless detection of dry bulk solids in containers, pipes or chutes. Reliable fill level and limit detection. • simple retrofitting • detection through all nonconductive walls • up to 1,000 °C possible with ceramic mounting • insensitive to material caking • usable for profiles up to 25 m
STACKFLOW 100 - Mikro-wenturi prędkość spalin cem

STACKFLOW 100 - Mikro-wenturi prędkość spalin cem

Flue gas flowmeter for continuous measurement of gas velocity, temperature and pressure in exhaust gas ducts (chimneys or flue pipes). Measured parameters:Flue-gas velocity Technology:Micro-venturi Measurement/Monitoring capability:3 – 30 m/s Stack/Duct diameter suitability:300 mm up to 1,5 m Flue gas temperature: up to 400 °C Baghouse:Yes Cartridge Filter:Yes Ceramic Filter:Yes Coalescent Filter:Yes Cyclone:Yes Electrostatic Precipitator (ESP):Yes Wet Electrostatic Precipitator (WESP):Yes
PM162M - Automatyczny sekwencyjny pobornik cząstek

PM162M - Automatyczny sekwencyjny pobornik cząstek

PM162M is a sequential automatic sampling device for particulate matter in the ambient air. The particles are sampled at constant flow rate (1 m3/h or 2.3 m3/h) and collected on filters for gravimetric weighing and possible physicochemical laboratory analysis. Measured parameter:Particulates Technology:Sampling Temperature range:+5°C to +40°C Data storage:> 6 months Included I/O:4 AI/4 AO/4 RC/6 DC