Sterowane pomiary radarowe Czas Lotu Levelflex FMP50
Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Measuring Principle:Guided radar
Characteristic / Application:Basic device; Rod probe, Rope probe; Integrated data memory, Factory precalibrated, Reliable measuri
Supply / Communication:2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus); 4-wire (HART)
Accuracy:Rod probe: +/- 2 mm (0.08 in); Rope probe: +/- 2 mm (0.08 in)
Ambient temperature:-40...+80 °C; (-40...+176 °F)
Process temperature:-20...+80 °C; (-4...+176 °F)
Process pressure absolute / max. overpressure limit:Vacuum...6 bar,; (Vacuum...87 psi)
Main wetted parts:Rod probe: 316L, PPS, Viton; Rope probe: 316, PPS, Viton
Process connection:Thread:; G 3/4, MNPT 3/4; Flange:; UNI Flange
Sensor length:Rod probe: 4 m (13 ft); Rope probe: 12 m (40 ft)