Produkty dla mps 5172 tranzystor (11)

Moduł czujnika dla Pt1000, 0...+300 °C, 20 mA - Moduły/Przetworniki temperatury

Moduł czujnika dla Pt1000, 0...+300 °C, 20 mA - Moduły/Przetworniki temperatury

The B+B measuring transducer module Pt1000 with current output 4-20mA, is an accurate reliable digital measuring transducer in a miniaturised PCB design with modern ASIC technology - digitally calibrated for connecting Pt1000 sensors. Name:Measuring transducer module Temperature measuring range:0...+300 °C Sensor:Platinum sensor Pt1000 , resistance characteristic DIN/IEC 60751 Measuring current:<300 µA Accuracy:<0.5% Output signal:4…20 mA, two wire Operating voltage:10...30 V DC Overvoltage protection:Varistor and RC-filter Permissible load:Ra[Ω]≤(Uv[V]-10V) / 0,02 A (only in case of 4…20 mA) Application temperature:-20...+80 °C Connection:Solder termination Dimensions:(LxWxH) 27 x 15 x 5 mm Scope of delivery:Our Pt1000 sensors are not included in scope of delivery, please order separately. Weight:0.002 kg
Wzmacniacz pomiarowy - 9250/9251 - Wzmacniacz pomiarowy - 9250/9251

Wzmacniacz pomiarowy - 9250/9251 - Wzmacniacz pomiarowy - 9250/9251

Il mondo futuro di automazione presenta le sfide quali rete, la velocità, l'accuratezza, l'integrazione e la convenienza. CARATTERISTICHE — Pronto ad usare con c'è ne faccia del sensore per i vostri bisogni di misura, indipendente del produttore — Configurazione ultraveloce del pulsante — Riconoscimento automatico del sensore dovuto lo spaccapietre TEDS — Interfaccia estensibile di fieldbus via il regolatore del bus — Ethernet di sostegni ha basato i fieldbuses come PROFINET, EtherCAT, interfaccia dell'ingresso/uscita di EtherNet/IP oder — Esportazione sincrona di fino a 8 canali di misura via il regolatore del bus — Funzione completa dell'esportazione di misura-dati — Adatto a misure della forza, di pressione, di spostamento, di velocità di rotazione e di coppia di torsione, compreso le misure combinate — Tari la funzione tramite pulsante o i segnali dell'ingresso/uscita per ogni amplificatore 9250 Tipo:di segnale Funzione secondaria:di misura Altre caratteristiche:fieldbus, per pressione, multicanale,
Konwerter sygnałów, Przetwornik sygnałów

Konwerter sygnałów, Przetwornik sygnałów

Signalkonverter SK20 von SSI Geber Signalen nach Analog 0...10V, 0/4...20mA Konvertierung von SSI-Daten an Analoge Geräte. 16Bit Auflösung 1ms Wandelrate. Lupen/Fensterfunktion. Teach-In Programmierung Eingangssignal: SSI Datenformat: 13/25 Bit Standalone, 8 - 25 Bit Parallelbetrieb Code: Gray- / Binärcode Taktfrequenz: 230 kHz Standalone, 70 - 600kHz Parallelbetrieb Signalausgang: 0-10V, 0/4-20mA Auflösung: 16Bit max. Fehler: 0,1% (Strom) 0,2% (Spannung) Schutzart: IP20 Versorgungsspannung: 24V DC
Potencjometr Alps

Potencjometr Alps

Alps ist als Hersteller von Potentiometern seit Jahrzenten weltweit bekannt. Neben den typischen Audioanwendungen werden Alps Proukte immer stärker auch im Automotive Bereich eingesetzt. Als autorisierter Distributor der ALPS ELECTRIC JAPAN können wir Ihnen sämtliche Produkte anbieten. Unser großes Lager ermöglicht es ebenfalls auch kleinere Mengen liefern zu können. Bezeichnung:RK16 Herkunftsland:Japan Typ:Drehpotentiometer sonstiges: mit u. ohne Motor
Miniaturowe przekaźniki - OW 5699_SMD

Miniaturowe przekaźniki - OW 5699_SMD

• According to DIN EN 61810-1, DIN EN 60664-1 • Power miniature relay for SMD mounting • High switching power AC 250 V / 5 A • High dielectric strength 4 kV • High limiting continuous current Ith = 5 A • Compact size V = 2,47 cm3 • Safe separation L + K ≥ 5,5 mm EN 50178 Function:Power miniature relay, SMD Type of relay:monostabil Contact material:AgSnO2; AgNi Continuous current:5 A Nominal voltage UN DC:4,5 - 48 V Voltage Range UN:0,75 - 1,6 V Test voltage (AC) contact set - coil:≥ 4 kV eff Clearance and creepage distances, contact set - coil ≥:5,5 mm Temperature range (- / +):40 - 80 °C Protection type:RT III (wash-tight) Size L x W x H:20,2 x 10,1 x 13,5 mm Approvals:cRUus Relay type:OW 5699_SMD
Wzmacniacz pomiarowy - 9250/9251 - Wzmacniacz pomiarowy - 9250/9251

Wzmacniacz pomiarowy - 9250/9251 - Wzmacniacz pomiarowy - 9250/9251

El mundo futuro de la automatización presenta desafíos tales como establecimiento de una red, velocidad, exactitud, integración y rentabilidad. CARACTERÍSTICAS — Listo para utilizar con ningunos haga del sensor para sus necesidades de la medida, independiente del fabricante — Configuración ultrarrápida del botón — Reconocimiento automático del sensor debido al separador TEDS — Interfaz extensible del fieldbus vía el regulador del autobús — Ethernet de las ayudas basó fieldbuses como PROFINET, EtherCAT, interfaz de la entrada-salida de EtherNet/IP oder — Exportación síncrona de hasta 8 canales de la medida vía el regulador del autobús — La instalación completa de la exportación de los medida-datos — Conveniente para la fuerza, la presión, la dislocación, la velocidad rotatoria y las medidas del esfuerzo de torsión, incluyendo medidas combinadas — Destare la instalación vía el botón o las señales de la entrada-salida para cada amplificador 9250 Tipo:de señal Función secundaria:de medidas Otras características:fieldbus, para galga extensométrica, Otras características:para celda de carga, para presión, Otras características:multivías, 8 canales
Cyfrowy czujnik wilgotności/temperatury HYT939, ciśnienie... - Czujniki wilgotności

Cyfrowy czujnik wilgotności/temperatury HYT939, ciśnienie... - Czujniki wilgotności

Precision, reliability and long-term stability are the main characteristics for our digital humidity and temperature sensors with I²C interface. Name:Digital humidity and temperature sensor Humidity measuring range:0...100% RH Humidity accuracy:±1.8% RH at +23 °C Digital interface:I²C, adress 0x28 or alternative adress Hysteresis:<±2% RH Humidity resolution:0.02% RH Linearity error humidity:<±1% RH Response time humidity:<10 s with metal line filter Tk residual error:0.05% RH/K (at 0...+60 °C) Long-term drift humidity:<0.5% RH/a Humidity measuring principle:capacitive polymer humidity sensor Temperature measuring range:-40...+125 °C Accuracy:±0.2 °C (at 0...60 °C) Reproducibility temperature:±0.1 K Response time temperature:<10 s with metal line filter Resolution:0.015 °C Long-term drift temperature:<0.05 K/a Temperature measuring principle:PTAT (integrated) Pressure resistance:16 bar Operating voltage:2.7...5.5 V Connection:TO39 Footprint Dimensions:Ø9x H5.2 mm Current consumption:typ. <22 µA bt 1 Hz measuring rate, 850 µA maximal Weight:0.001 kg
Cyfrowy czujnik wilgotności/temperatury HYT939 - Czujniki wilgotności

Cyfrowy czujnik wilgotności/temperatury HYT939 - Czujniki wilgotności

Precision, reliability and long-term stability are the main characteristics for our digital humidity and temperature sensors with I²C interface. Name:Digital humidity and temperature sensor Humidity measuring range:0...100% RH Humidity accuracy:±1,8% RH at +23°C (0...90% RH) Digital interface:I²C, adress 0x28 or alternative adress Hysteresis:<±2% RH Humidity resolution:0.02% RH Linearity error humidity:<±1% RH Response time humidity:<10 s with metal line filter Tk residual error:0.05% RH/K (at 0...+60 °C) Long-term drift humidity:<0.5% RH/a Humidity measuring principle:capacitive polymer humidity sensor Temperature measuring range:-40...+125 °C Accuracy:±0.2 °C (at 0...60 °C) Reproducibility temperature:±0.1 K Response time temperature:<10 s with metal line filter Resolution:0.015 °C Long-term drift temperature:<0.05 K/a Temperature measuring principle:PTAT (integrated) Operating voltage:2.7...5.5 V Connection:TO39 Footprint Dimensions:Ø9x H5.2 mm Current consumption:typ. <22 µA bt 1 Hz measuring rate, 850 µA maximal Weight:0.0008 kg
Cyfrowy czujnik wilgotności/temperatury HYT271-S - Czujniki wilgotności

Cyfrowy czujnik wilgotności/temperatury HYT271-S - Czujniki wilgotności

Precision, reliability and long-term stability are the main characteristics for our digital humidity and temperature sensors with I²C interface. Name:Digital humidity and temperature sensor Humidity measuring range:0...100% RH Humidity accuracy:±1,8% RH at +23°C (0...90% RH) Digital interface:I²C, adress 0x28 or alternative adress Reproducibility humidity:0.2% RH Hysteresis:<±2% RH Humidity resolution:0.03% RH Linearity error humidity:<±1% RH Response time humidity:<4 s Tk residual error:0.05% RH/K (at 0...+60 °C) Long-term drift humidity:<0.5% RH/a Humidity measuring principle:capacitive polymer humidity sensor Temperature measuring range:-40...+125 °C Accuracy:±0.2 °C (at 0...60 °C) Reproducibility temperature:±0.1 K Resolution:0.015 °C Response time temperature:<5 s Long-term drift temperature:<0.05 K/a Temperature measuring principle:PTA (integrated) Operating voltage:2.7...5.5 V Connection:SIL-connection, pluggable, RM 1.27 mm Dimensions:(LxWxH) 10.2 x 5.1 x 1.8 mm Current consumption:typ. <22 µA bt 1 Hz measuring rate, 850 µA maximal Weight:0.0006 kg
Czujnik temperatury platynowy Pt500, tolerancja F 0.3,... - Automatyka budynkowa

Czujnik temperatury platynowy Pt500, tolerancja F 0.3,... - Automatyka budynkowa

The Pt500 temperature sensors are long term-stable, highly accurate and intermateable. The sensors are available in packs of 5. Name:Platinum temperature sensor Sensor element:Pt-thin film measuring resistance Temperature measuring range:-70...+500 °C Temperature Coefficient:TK = 3850 ppm/K Accuracy:Class F 0,3 (Class B) DIN EN 60751 conform Connection wires:NiPt coated wire Connection length:Wire length 10 mm ±1 mm Long-term stability:Max. R0-Drift 0.04% after 1000 h at 500 °C Shock resistant:min. 40g speed-up at 10 to 2000 Hz, depending on way of installation Shock strength:min. 100 g speed-up ati 8 ms half sinusoidal wave, depending on montage Environmental conditions:unprotected, to be used in dry conditions only Self-heating:0,4 k/mW at 0 °C Insulating resistance:>100 MΩ at 20 °C, >2 MΩ at 500 °C Response time temperature:T0,5= 0,05 s;T0,9= 0,15 s; Airflow (v=2 m/s) : T0,5= 3,0 s; T0,9= 10,0 s Measuring current:0,3...1,0 mA 500 Ω: 0,1...0,7 mA 1000Ω: 0,1...0,3 mA Dimensions:(LxWxH) 2.3x 2.1x 0.9 mm Packing unit:5 pieces Weight:0.0044 kg
Platynowy czujnik temperatury Pt100, tolerancja F 0,15,... - Automatyka budynkowa

Platynowy czujnik temperatury Pt100, tolerancja F 0,15,... - Automatyka budynkowa

The Pt100 temperature sensors are long term-stable, highly accurate and intermateable. The sensors are available in packs of 5. Name:Platinum temperature sensor Sensor element:Pt-thin film measuring resistance Temperature measuring range:-70...+500 °C Scope:-50...+300 °C Accuracy:F 0,15 (Cl. A) Temperature Coefficient:TK = 3850 ppm/K Connection wires:NiPt coated wire Connection length:Wire length 10 mm ±1 mm Long-term stability:Max. R0-Drift 0.04% after 1000 h at 500 °C Shock resistant:min. 40g speed-up at 10 to 2000 Hz, depending on way of installation Shock strength:min. 100 g speed-up ati 8 ms half sinusoidal wave, depending on montage Environmental conditions:unprotected, to be used in dry conditions only Insulating resistance:>100 MΩ at 20 °C, >2 MΩ at 500 °C Self-heating:0,4 k/mW at 0 °C Response time temperature:T0,5= 0,05 s;T0,9= 0,15 s; Airflow (v=2 m/s) : T0,5= 3,0 s; T0,9= 10,0 s Measuring current:0,3...1,0 mA 500 Ω: 0,1...0,7 mA 1000Ω: 0,1...0,3 mA Dimensions:(LxWxH) 2.3x 2.1x 0.9 mm Packing unit:5 pieces Weight:0.0044 kg