iTHERM TT411 Rura ochronna
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes.
Measuring Principle:Fabricated Thermowell
Characteristic / Application:metric style; hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA); hygienic process connections; Qu
Head connection:QuickNeck; male thread:; M24x1,5; G3/8"
Maximum standard immersion length:4.000 mm (157,48")
Process connection:compression fitting; weld in adaptor; clamp connections acc. to ISO2852; screwed pipe joint acc. to
Thermowell root diameter:6,0 mm (0,24"); 9,0 mm (0,35"); 12,7 mm (0,5")
Medium contact material:1.4435 delta-ferrit < 1%; 316L
Wetted part finishing (Ra):< 0,76 μm (29,92 µin); < 0,38 μm (14,96 µin); < 0,38 μm (14,96 µin) electropolished
Tip shape:straight; reduced; tappered
Temperature range:-200...650 °C (-328...1.202 °F)