Produkty dla wypożyczalnia (55)

Delta T niskotonażowa bank 100 kW, 200 kW, 300 kW

Delta T niskotonażowa bank 100 kW, 200 kW, 300 kW

Rentaload offers a range of 100/200/300 kW high power load banks dedicated to testing in large rooms with several MW of IT power. With their low Delta T , they limit the overheating of computer rooms and thus overstress the air conditioning systems. In addition, their low heating prevents any damage to heat-sensitive peripheral equipment (lighting fibres, cables, fire detection system, etc.) Available in “ SMART” version thanks to their supervision software, they make it possible to collect extremely precise measurements (P/U/I/Delta T) during the tests. A sure way to add value to your tests .
200 kW Niskie Delta T Bank Obciążeniowy

200 kW Niskie Delta T Bank Obciążeniowy

Rentaload propose une gamme de bancs de charge de forte puissance 100/200/300 kW dédiée aux tests dans les grandes salles de plusieurs MW de puissance IT. Avec leur faible Delta T, ils limitent l’échauffement des salles informatiques et ainsi, de sur solliciter les systèmes de climatisation. De plus, leur faible échauffement évite toute dégradation sur les équipements périphériques sensibles à la chaleur (fibres luminaires, câbles, système de détection incendie, etc.) Disponibles en version “SMART” grâce à leurs logiciels de supervision, ils permettent de collecter des mesures extrêmement précises (P/U/I/Delta T) pendant les tests. Un moyen sûr d’apporter de la valeur ajoutée à vos tests.
ATS zewnętrzny

ATS zewnętrzny

Si vous souhaitez effectuer des tests de redondance pour vérifier vos installations, nous vous conseillons de louer ce boîtier ATS (Automatic Transfer Switch) en complément de votre banc de charge. Vous pourrez ainsi basculer la charge électrique entre la voie A et la voie B sans avoir à déconnecter et reconnecter les câbles. Cet ATS est valable pour les bancs rackables 7 kW classiques. Nous avons également des ATS pour les bancs 100/200/300 kW à Faible Delta T.
Test baterii

Test baterii

Rentaload operates throughout Europe in different business sectors to carry out battery tests for its customers. These tests, which aim, among other things, to check the condition of the batteries as well as their aging over time, have some specificities that you need to know. Discover on this page everything you need to know about battery tests. Why should you test your batteries? When should this type of test be performed? With what types of load banks? Also discover the sectors of activity in which we operate and the services we offer in addition to the rental of load banks.
Tymczasowe szafy rozdzielcze i skrzynki połączeniowe

Tymczasowe szafy rozdzielcze i skrzynki połączeniowe

Rentaload s’adapte à toutes les configurations électriques des salles à tester. Cela peut impliquer le déploiement d’armoires de distribution électrique temporaire. L’armoire de distribution électrique temporaire 210 kW permet de connecter jusqu’à 10 bancs de charge 21 kW – 32A/400V (ou 30 bancs rackables en 220V 32A). Raccordée en entrée par des câbles 120 mm² équipés de Powerlocks, l’armoire peut ainsi être alimentée par le tableau électrique principal de la salle informatique. Montée sur armature métallique avec roulettes, elle est facilement déplaçable d’une salle à l’autre.
21kW Mini Wieża

21kW Mini Wieża

Rentaload offers two types of “ mini-tower ” for rent: the “basic” mini-tower and the “premium” mini-tower . They are the equivalent of the 21 KW air heater load bank but are each made up of 3 rackable 7 KW load banks. The premium mini-tower offers, in addition to the basic mini-tower, a better Delta T and an integrated ATS . The latter makes it possible to carry out double chain tests. This mini-tower is therefore compatible with all 2N type electrical infrastructures. These mini-towers can be adapted to different power configurations by adding or removing a 7kW module. This equipment is more reliable and more robust than standard air heaters, in particular thanks to their integrated circuit breakers. Indeed, they make it possible to protect the load bank in the event of electrical overcurrent. Power:21kW Resolution:0.5kW Dimensions Height:878mm Dimension Width:19 inches (614mm) Dimension Depth:569mm
Półki i Deflektory

Półki i Deflektory

Rentaload vous propose à la location et en complément des bancs de charge rackables, des étagères 19 et 21 pouces sans vis, ni écrou. Ce sont des étagères faciles et rapides à monter. Elles vous permettront de positionner vos équipements à l’intérieur de vos baies informatiques à l’emplacement souhaité. Parmi nos accessoires, nous proposons aussi à la location des déflecteurs pour les bancs de charge à faible Delta T 100/200/300 kW. Ces derniers permettent de dévier l’air du banc de charge et de le rediriger vers le haut. Cela permet de limiter l’échauffement des salles informatiques et donc de sur solliciter les systèmes de climatisation. Leur faible échauffement évite ainsi toute dégradation sur les équipements périphériques sensibles à la chaleur (fibres luminaires, câbles, système de détection incendie, etc.). Avec les déflecteurs, on a en fait, une meilleure répartition de la chaleur au sein des salles IT.
Bank obciążeniowy rezystancyjny od 50 kW do 2,4 MW

Bank obciążeniowy rezystancyjny od 50 kW do 2,4 MW

Rentaload offers for rent a wide range of resistive load banks ranging from 50 kW to 2.4 MW : 50 kW, 100 kW, 200 kW, 300 kW, 500 kW, 600 kW, 2.4 MW… A modular range that offers load banks on wheels, on a trailer or on a flatbed. It is ideal for testing generators, testing batteries or inverters (indoors and outdoors). Our equipment is also suitable for different sectors of activity: data centre, industrial, tertiary, maritime and naval, health and hospitals, etc. Test reports can also be edited. It is therefore up to you to choose the power you want (from 1 kW to several MW). Power:50kW to 2.4MW Voltage:230V / 400V / Single / 3-phase Dimensions Height:700mm Dimension Width:19 inches (410mm) Dimension Depth:490mm Notches:Cable HO7RNF Resolution:1kW
100 kW Niska Delta T Bank obciążeniowy

100 kW Niska Delta T Bank obciążeniowy

Rentaload propose une gamme de bancs de charge de forte puissance 100/200/300 kW dédiée aux tests dans les grandes salles de plusieurs MW de puissance IT. Avec leur faible Delta T, ils limitent l’échauffement des salles informatiques et ainsi, de sur solliciter les systèmes de climatisation. De plus, leur faible échauffement évite toute dégradation sur les équipements périphériques sensibles à la chaleur (fibres luminaires, câbles, système de détection incendie, etc.) Disponibles en version “SMART” grâce à leurs logiciels de supervision, ils permettent de collecter des mesures extrêmement précises (P/U/I/Delta T) pendant les tests. Un moyen sûr d’apporter de la valeur ajoutée à vos tests.
Test systemu klimatyzacji

Test systemu klimatyzacji

Rentaload operates in the UK, Ireland, France and across Europe in across a variety of business sectors in order to carry out air conditioning tests for its customers. These tests are carried out using our air heater load banks. They allow you to check the functionality and efficiency of all your air conditioning systems. These tests are therefore very important and highly recommended. Find out on this page everything you need to know about air conditioning tests. Why should you test your cooling system? When exactly should it be tested? With which load banks? Also discover the sectors of activity in which we operate and the services we offer in addition to the rental of our load banks.
Wynajem Banków Obciążeniowych

Wynajem Banków Obciążeniowych

Rentaload propose à la location une large gamme de bancs de charge SMART et connectés, allant de 6 KW à 2,4 MW. Des bancs de charge résistifs, inductifs ou bien en courant continu. Des équipements rackables aux équipements portatifs de grosse puissance, nous aurons de quoi répondre à tous vos besoins. Les équipements Rentaload s’adaptent en effet à tous les types d’environnements, des petites salles de datacenter équipées de racks jusqu’aux grandes salles IT de 10 MW et plus !
Bank obciążeniowy dla grzejnika jednostkowego 21 kW

Bank obciążeniowy dla grzejnika jednostkowego 21 kW

Rentaload offers rental of 21 kW unit heater load banks, usable both in single- phase (230V) and three- phase (400V). This is an intermediate solution between rackable load banks and high power 100/200/300 kW Low Delta T load banks. It is a perfect solution when your racks are not yet in place, but that you still want to have a good distribution of the thermal load in your computer room. In addition, this equipment is perfectly designed to make your life easier (small wheels, leather handles, light weight). You can therefore easily move them and pass them through doors, stairs or even ramps. As you will have understood, it is an extremely handy and practical product! Power:21kW Voltage:230V / 400V Resolution:1kW Dimensions Height:700mm Dimension Width:490mm Dimension Depth:490mm
Testowanie inwertera

Testowanie inwertera

Rentaload operates throughout Europe in different sectors of activity in order to carry out inverter tests . These tests aim to validate the correct operation of your inverters. These tests are not mandatory but strongly recommended to ensure the security and reliability of your infrastructure. Find out on this page everything you need to know about inverter testing. Why should inverters be tested? When should this type of test be performed? With what types of load banks? Also discover the sectors of activity in which we operate and the services we offer in addition to the rental of load banks.
Test generatora

Test generatora

Rentaload operates in France and Europe in various sectors of activity in order to carry out tests on generators . These periodic tests are strongly recommended or even mandatory for certain sectors of activity. Find out on this page everything you need to know about generator set testing. Why should you test your group? When exactly should it be tested? With which load banks? Also discover the sectors of activity in which we operate and the services we offer in addition to the rental of our load banks.
Wynajem banku obciążeniowego

Wynajem banku obciążeniowego

Rentaload offers a wide range of SMART and connected load banks for rental, ranging from 6 kW to 2.4 MW. Resistive, inductive or direct current load banks. From rackmount equipment to high-power portable equipment, we have something to meet all your needs. Rentaload equipment adapts to all types of environments, from small data center rooms equipped with racks to large IT rooms of 10 MW and more!
Zewnętrzne TTY

Zewnętrzne TTY

If you want to carry out redundancy tests to check your installations, we advise you to rent this ATS (Automatic Transfer Switch) box in addition to your load bank. This will allow you to switch the electrical load between channel A and channel B without having to disconnect and reconnect the cables.
Indukcyjna banki obciążeniowej 501 KVA i 671 KVA

Indukcyjna banki obciążeniowej 501 KVA i 671 KVA

Rentaload offers two trailer-mounted mobile inductive load banks for hire: 501 KVA 671 KVA They can be coupled together to reach a total power of 1172 KVA. With their supervision software, you can send them instructions and collect extremely precise data during your tests (P/U/I/). These are SMART equipment that will bring real added value to your tests. They also adapt to different sectors of activity (data center, industry, health and hospitals, maritime and naval, etc.) and are perfectly suited to testing generator sets, for example. It is a range geared towards the “service and maintenance” of equipment.
Testy uruchomienia dla centrów danych

Testy uruchomienia dla centrów danych

Rentaload propose pour les tests de commissioning sur les datacenters la location de bancs de charge SMART et connectés. Ces équipements permettent de tester tous les niveaux de redondance électriques et thermiques des infrastructures, dès la fin de la construction, de la rénovation ou bien lors d’opération de maintenance : Test de la chaîne électrique principale ; Test de la chaîne électrique de secours et test des équipements de secours ; Test du système de refroidissement des salles. Rentaload propose aussi en complément de la location des bancs de charge tout un panel de services associés (livraison, installation et raccordement, assistance aux tests ou commissioning complet).
Mini-Tour 21kW

Mini-Tour 21kW

Rentaload propose à la location deux types de “mini-tours” : la mini-tour “basic” et la mini-tour “premium”. Elles sont l’équivalent du banc de charge aérotherme 21 KW mais sont composées chacune de 3 bancs de charge rackables 7 KW. La mini-tour premium propose, en plus de la mini-tour basic, un meilleur Delta T et un ATS intégré. Ce dernier permet d’effectuer des tests en double chaîne. Cette mini-tour est donc compatible avec toutes les infrastructures électriques de type 2N. Ces mini-tours peuvent s’adapter à différentes configurations de puissance par l’ajout ou la suppression d’un module 7kW. Ces équipements sont plus fiables et plus robustes que des aérothermes standards notamment grâce à leurs disjoncteurs intégrés. En effet, ils permettent de protéger le banc de charge en cas de surintensité électrique.
Testy uruchomieniowe dla centrów danych

Testy uruchomieniowe dla centrów danych

Rentaload offers for commissioning tests on datacentres the rental of SMART and connected load banks . This equipment makes it possible to test all levels of electrical and thermal redundancy of infrastructures, from the end of construction, renovation or during maintenance operations: Test of the main electric chain; Emergency electrical chain test and emergency equipment test; Test of the room cooling system. Rentaload also offers, in addition to the rental of load banks, a whole range of associated services (delivery, installation and connection, assistance with tests or complete commissioning). Today, Rentaload’s expertise in this type of test is known and recognised throughout Europe.
Czujniki Wilgotności i Temperatury

Czujniki Wilgotności i Temperatury

Rentaload propose aussi à la location un certain nombre d’accessoires d’instrumentation et de mesure. Ils complètent les données récoltées à travers les logiciels. Caméra thermique pour analyser les différents points chauds des salles IT ; Anémomètre pour analyser la vitesse d’air ; Analyseurs pour donner des informations sur le réseau ; Capteurs de température pour analyser la température de la salle informatique ; Capteurs d’humidité pour analyser l’humidité de la salle ; Etc. Ces accessoires peuvent être loués indépendamment ou en complément des logiciels Rentalab et EkkoSense, en fonction de vos besoins.
300 kW Niska Delta T Bank obciążeniowy

300 kW Niska Delta T Bank obciążeniowy

Rentaload propose une gamme de bancs de charge de forte puissance 100/200/300 kW dédiée aux tests dans les grandes salles de plusieurs MW de puissance IT. Avec leur faible Delta T, ils limitent l’échauffement des salles informatiques et ainsi, de sur solliciter les systèmes de climatisation. De plus, leur faible échauffement évite toute dégradation sur les équipements périphériques sensibles à la chaleur (fibres luminaires, câbles, système de détection incendie, etc.) Disponibles en version “SMART” grâce à leurs logiciels de supervision, ils permettent de collecter des mesures extrêmement précises (P/U/I/Delta T) pendant les tests. Un moyen sûr d’apporter de la valeur ajoutée à vos tests.
Akcesoria do instrumentów

Akcesoria do instrumentów

Rentaload also offers a number of instrumentation and measurement accessories for hire. They complete the data collected through the software. Thermal camera to analyse the various hot spots in IT rooms; Anemometer to analyse air speed; Analysers to provide network information; Temperature sensors to analyse computer room temperature; Humidity sensors to analyse room humidity; etc These accessories can be rented independently or in addition to Rentalab and EkkoSense software, depending on your needs.
Nasze akcesoria pomiarowe do banków obciążeniowych

Nasze akcesoria pomiarowe do banków obciążeniowych

Rentaload propose aussi à la location un certain nombre d’accessoires d’instrumentation et de mesure. Ils complètent les données récoltées à travers les logiciels. Caméra thermique pour analyser les différents points chauds des salles IT ; Anémomètre pour analyser la vitesse d’air ; Analyseurs pour donner des informations sur le réseau ; Capteurs de température pour analyser la température de la salle informatique ; Capteurs d’humidité pour analyser l’humidité de la salle ; Etc. Ces accessoires peuvent être loués indépendamment ou en complément des logiciels Rentalab et EkkoSense, en fonction de vos besoins.
Bank obciążeniowy prądu stałego

Bank obciążeniowy prądu stałego

Rentaload offers the rental of direct current load banks, allowing the reliability of a battery to be tested. Testing using load banks validates the operational performance and battery life of a system. It tests the inverter and generator under load conditions. Indeed, these tests, most often performed during preventive maintenance, can determine the condition of the inverter’s batteries and battery packs (or “strings”) and indicate whether individual cells are in good condition or approaching end of life and must be replaced. The load bank test will ensure that the backup system batteries will work together as expected when called upon to support a critical load.