Produkty dla instrumenty (1066)

AF22e Rozcieńczenie - Analizator Dwutlenku Siarki

AF22e Rozcieńczenie - Analizator Dwutlenku Siarki

QAL1 zertifiziertes und US-EPA zugelassenes UV-Fluoreszenz-Gasüberwachungssystem für die Überwachung von SO2 im Bereich von 0-10 ppm oder 0-1 ppm SO2:0-300 / 6000 ppb H2S:0-150 ppb Probenahme-Technologie:Verdünnung Probentransfer:nicht beheiztes Polyrohr Rückspülfunktion:Ja Bereichsinjektion:Ja
MIR IS - In-situ ściśle sprzężony analizator wielogazowy

MIR IS - In-situ ściśle sprzężony analizator wielogazowy

A complete “all in one" compact system, for multigas measurements, based on the fieldproven MIR 9000 analyzer and onboard SEC sampling system. Fast & simultaneous measurement of up to 10 gases among HCl, NO, NO2 (NOx), SO2, CO, CO2, HC, CH4 (TOC), HF, N2O, O2, at the sampling location. • integrated sample drying & system conditioning, no sample line necessary • designed for measuring wet & corrosive samples • complete CEMS in one cabinet combines infrared analyzer, sample conditioning • highly accurate, excellent calibration stability with automatic optional check
MIR 9000 P - Przenośny analizator wielogazowy NDIR-GFC

MIR 9000 P - Przenośny analizator wielogazowy NDIR-GFC

The MIR 9000 P measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the nondispersive infrared method (NDIRGFC) with gas filter correlation. O2 is measured by a builtin SRM paramagnetic sensor. • operational at any time due to standby mode • remote access to full operation • quick installation • onsite preparation of report elements • time saving all along emission testing process
LCPD BOX - Podgrzewany system pobierania próbek

LCPD BOX - Podgrzewany system pobierania próbek

Extraktives und beheiztes Probenahmesystem aus Edelstahl mit integriertem beheizten Partikelfilter. Probenahmesystem:Heiße nasse Extraktion (Nassbasisanalyse) Sondenrohr:Edelstahl Probenahmeleitung:beheizt
AutoCal - Automatyczna Jednostka Kalibracyjna dla UT-3000

AutoCal - Automatyczna Jednostka Kalibracyjna dla UT-3000

Dient der automatischen Kalibrierung des Mercury Ultratracers UT-3000. Reinheit des enthaltenen Hg:99,999999% Genauigkeit des T-Sensors:0,01 °C
UT-3000 NG mobilny - Mobilny analizator ultratrace rtęci dla gazu ziemnego

UT-3000 NG mobilny - Mobilny analizator ultratrace rtęci dla gazu ziemnego

Perfectly adapted to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants. Measuring principle:Amalgamation (MI GoldTrap), cold vapor atomic absorption (CVAAS) at 253.7 nm UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Measured component:Total Gaseous Mercury (TGM) Detection limit:1 pg absolutely or 0.1 ng/m³
ALERT WYCIEKU 73 - Monitor pyłu/wycieku filtra elektrodynamicznego

ALERT WYCIEKU 73 - Monitor pyłu/wycieku filtra elektrodynamicznego

Standalone filter dust leak monitor (0100%) for filter emissions monitoring after baghouses, cartridge filters, cyclones etc. where performance approvals are not required. • reliable monitoring of leaking and broken bags in dust collectors • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs
VM-3000 - Monitor Par Rtęci

VM-3000 - Monitor Par Rtęci

Der VM-3000 misst kontinuierlich die Hg-Konzentration in Luft und Gasen. Er eignet sich perfekt für die kontinuierliche Überwachung der Luftqualität, für das Umwelt-Monitoring, die Qualitätskontrolle oder die Emissionsüberwachung. Messprinzip:Kaltdampf UV-Absorption (CVAAS) bei 253,7 nm UV-Quelle:Elektrodenlose Hg-Niederdrucklampe (EDL) Stabilisierung:Referenzstrahl-Technik Optische Zelle:Quarzglas (Suprasil) Nachweisempfindlichkeit:0.1 μg/m³
MVS - System zarządzania CEMS przez multipleksowanie

MVS - System zarządzania CEMS przez multipleksowanie

MVS 2M is a multichannel system allowing to distribute two, three or four channels of fluids and signals to a gas monitoring system (GMS). Operating temperature:+5°C to +40°C Communication port:RS232/RS422, Ethernet
VIEW 370 - Monitor pyłu elektrodynamiczny

VIEW 370 - Monitor pyłu elektrodynamiczny

Multisensor dust monitor designed for high quality emission measurement in industrial stacks after bag filters, cartridge filters, cyclones and process driers. Advanced probe electrification multisensor dust monitor designed for high quality emission measurement in industrial stacks where regulatory approvals are not necessary. • PRO version permits multichannel networked system for plantwide monitoring of emissions (for up to 32 sensors) • full colour, icondriven menu and display • two independent alarm set points • relative dust reading on clear scale 0100% • dust 'overrange' icon • security setting • digital signal processing • field upgradeable
MMS-NG - Automatyczne monitorowanie rtęci w gazie ziemnym

MMS-NG - Automatyczne monitorowanie rtęci w gazie ziemnym

Automatic systemdesigned for continuous mercury monitoring in natural gas even in hazardous zones (ATEX, IEC-Ex). Measuring principle:Amalgamation (MI GoldTrap), cold vapor atomic absorption (CVAAS) at 253.7 nm UV-Source:Electrodeless low pressure mercury lamp (EDL) Stabilization method:Reference beam method Optical cell:Fused silica (Suprasil), l: approx. 230mm, heated approx. 45° Measured component:Total Gaseous Mercury (TGM) Detection limit:1 pg absolutely or 0.1 ng/m³
AMESA-D - System długoterminowego pobierania próbek dla dioksyn i furanów

AMESA-D - System długoterminowego pobierania próbek dla dioksyn i furanów

QAL1 und MCERTs zertifiziertes Langzeitprobenahmesystem für Dioxine, Furane und PCBs. Messbereich:0.0001–10 ng I-TEQ / m³ Probenahmeintervall:6 h – 6 Wochen Rauchgastemperatur:bis 70°C ohne Kühlwasser / bis zu 400˚C mit Kühlwasser Rauchgasgeschwindigkeit:1 bis zu 30 m/s
MP101M - Ciągły, automatyczny monitor cząstek zawieszonych

MP101M - Ciągły, automatyczny monitor cząstek zawieszonych

PM10, PM2.5 and PM1 fine dust concentration measurement in the range 0-10,000 μg/m3 according the ISO 10473 Standard. QAL 1 certified and US EPA approved. Measured parameter:PM10, PM2.5, PM1, TSP Technology:Beta Ray Attenuation US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 10 000 μg/m3 Measurement units:µg/m3 Lower Detectable Limit (2σ):0.5 μg/m3 (24h average)
PM Cairsens® PM1, PM2.5 i PM10 - Ciągłe monitorowanie w czasie rzeczywistym PM1, PM2.5 i PM10

PM Cairsens® PM1, PM2.5 i PM10 - Ciągłe monitorowanie w czasie rzeczywistym PM1, PM2.5 i PM10

Messung von PM1- und PM10-Konzentrationen, mit erhöhter Präzision für PM2,5. Messbare Parameter:PM1, PM2.5 & PM10 Messbereich:0 – 1 000 µg/m3 Partikelgröße ø:0.3 – 10 µm Zertifizierte Nachweißgrenze:< 5 µg/m3
ZAG7001 - Generator Powietrza Zero

ZAG7001 - Generator Powietrza Zero

Null-Luft-Generator gibt kontinuierlich bis zu 20 Standardliter pro Minute (SLPM) trockene, schadstofffreie Luft ab. Standardliter pro Minute (SLPM):20 Interner Kompressor:Ja Innentrockner:Typ PSA
Cairsens® O₃ + NO₂ - Ciągłe pomiary O3 i NO2 w czasie rzeczywistym

Cairsens® O₃ + NO₂ - Ciągłe pomiary O3 i NO2 w czasie rzeczywistym

Mikro-Sensor für die präzise und zuverlässige Messung von O3 und NO2. Messbare Parameter:O3 + NO2 Messbereich (ppm):0 – 0.25 Zertifizierte Nachweisgrenze (ppm):0.02 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis 40
LEAK LOCATE 662 - Monitory wydajności filtrów

LEAK LOCATE 662 - Monitory wydajności filtrów

The LEAK LOCATE 662 is a digitally networked, multicompartment baghouse monitoring system providing remote observation of the condition of bag and cartridge filters. • reliable monitoring of leaking and broken bags in dust collectors • sensor configuration remotely via controller • manual sensor drift checks • probe check option for improved data integrity • reduces filter maintenance intervals, process downtime and filter costs
LGD 2M - Moduł detekcji gazu laserowego NH3 (TDLS)

LGD 2M - Moduł detekcji gazu laserowego NH3 (TDLS)

Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) Gas:NH3 Principle of detection:Tunable Diode Laser Spectrometry (TDLS) Ranges:0-100 / 0-20 ppm Precision 2σ :1.8 ppm @ 1 s; 0.8 ppm @ 10 s Response time:< 2 sec (T90) (at gas flow rate of 3 L/min) Cell temperature range:190°C Operating temperature:+15 to +50°C Communication:RS 232 Dimensions:Rack 19″ – 3U
DM 170 - Monitor emisji cząstek przez rozpraszanie światła

DM 170 - Monitor emisji cząstek przez rozpraszanie światła

The DM 170 is designed to comply with the TÜV suitability testing scheme to EN 15267 and for measuring dust concentrations in a wide range of industrial applications. Due to its wide dynamic range, the DM 170 may be used in combustion applications as well as in higher dust loading applications (such as power, cement and metals smelting, and in processes without filtration). Its simplicity and wide operating range makes it also ideally suited for process optimisation applications. • ProScatter™ backscatter sensor technology • Manual and remote Zero and Span checks available to ensure optimal instrument performance • purge flow fail sensor and optical shield options • nonintrusive system designed to operate in noncondensing stack environments • Singleside stack installation reduces contamination risk
QAL 991 - Zatwierdzony CEM cząstek QAL1

QAL 991 - Zatwierdzony CEM cząstek QAL1

Continuous emission monitor providing high quality emission measurement for low dust concentrations from dry industrial processes. Measured parameters:Dust Technology:ElectroDynamic™ Advanced Probe Electrification Measurement/Monitoring capability:0-1000 mg/m³ Stack/Duct diameter suitability:up to 8m Flue gas temperature:up to 500°C Baghouse:Yes Cartridge Filter:Yes Coalescent Filter:Yes Cyclone:Yes
VOC72e - Analizator lotnych związków organicznych

VOC72e - Analizator lotnych związków organicznych

Gas chromatography (GC) coupled with a PID detector. VOC monitor QAL1 certified to EN 14662-3, the newest standard for benzene measurement. Measured parameter:VOC (Benzene, Toluene, Ethylbenzene, m+p-Xylene, o-Xylene, 1,3 Butadiene) Technology:Gas Chromatography US-EPA Approval / QAL 1 Certification:Yes Measurement ranges:up to 1000 µg/m3 Measurement units:ppb, ppm, µg/m3 (user-selectable) Noise (σ):≤ 0.025 µg/m3 at 0.5 µg/m3 benzene Lower Detectable Limit (2σ):≤ 0.05% µg/m3 benzene Zero drift:≤ 4% / 15 days Span drift:< 1% / 7 days
Anemometr ultradźwiękowy dla Cairnet - Czujnik prędkości i kierunku wiatru

Anemometr ultradźwiękowy dla Cairnet - Czujnik prędkości i kierunku wiatru

Das Gerät misst die Windgeschwindigkeit und Windrichtung und wird über ein integriertes Solarpanel mit Strom versorgt. Es verfügt über eine wiederaufladbare Lithium-Batterie. Bereich der Windgeschwindigkeit:1 – 40 m/s Auflösung der Windgeschwindigkeit:1 m/s Empfindlichkeit der Windgeschwindigkeit:0,13 m/s Bereich der Windrichtung:0 – 359° Auflösung der Windrichtung:10° Empfindlichkeit gegenüber der Windrichtung:+/- 1.5°
AMESA-B - System długoterminowego pobierania próbek dla biogennego CO2

AMESA-B - System długoterminowego pobierania próbek dla biogennego CO2

Das AMESA-B dient zur kontinuierlichen Überwachung von biogenen CO2-Emissionen. So kann der klimaneutrale Anteil am gesamten CO2-Ausstoß ermittelt werden, für den dann keine Emissionshandelszertifikate nötig sind. Entnahmekapazität:5- 50 Nml/min Probenahmezeit:mehreren Stunden bis zu 1 Monat Umgebungstemperatur Standard:+5 °C bis +38 °C Umgebungstemperaturen mit Klimagerät:>+38 °C Umgebungstemperaturen mit Heizgerät:<+5 °C
MIR 9000 - Analizator wielogazowy NDIR-GFC

MIR 9000 - Analizator wielogazowy NDIR-GFC

Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2. MultiGas NDIRGFC analyzer (NonDispersive Infrared Gas Filter Correlation) measuring up to ten gases simultaneously, including Nitrogen Oxide (NO), Nitrogen Dioxide (NO2), Sulphur Dioxide (SO2), Carbon Monoxide (CO), even Hydrogen Chloride (HCl) and Hydrogen Fluoride (HF). • process optimization and environmental compliance • measurement of dry and corrosive samples • fast and simultaneous measurements of up to 10 gases • dry basis measurement • automatic cross interference correction
DIL-1 / MS-1 - System rozcieńczania

DIL-1 / MS-1 - System rozcieńczania

Ideal for mid-high to high concentrations, also for sampling locations in hazardous areas (ATEX). Maximum sample gas temperature:– standard probe: + 400°C; quartz probe: + 600°C Dilution rate:12/1 to 350/1 function of the type of critical orifice selected Accuracy of dilution rate:± 2 %
Cairsens® NH₃ - Ciągłe Monitorowanie w Czasie Rzeczywistym NH3

Cairsens® NH₃ - Ciągłe Monitorowanie w Czasie Rzeczywistym NH3

Spezifische Schadstoffmessung zur Überwachung von NH3. Messbare Parameter:NH3 Messbereich (ppm):0 – 25 Zertifizierte Nachweisgrenze (ppm):0.5 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis 40
Cairsens® SO₂ - Ciągły Pomiar SO₂ w Czasie Rzeczywistym

Cairsens® SO₂ - Ciągły Pomiar SO₂ w Czasie Rzeczywistym

Präzise und zuverlässige Echtzeitmessung von SO2. Messbare Parameter:SO2 Messbereich (ppm):0 – 1 Zertifizierte Nachweisgrenze (ppm):0.05 Auflösung (ppm):0.001 Temperaturbereich (°C):-20 bis +50
NG Sampling System 3000 - System przygotowania próbek dla gazu ziemnego

NG Sampling System 3000 - System przygotowania próbek dla gazu ziemnego

Probenaufbereitungssystem zur Entnahme von Probengas aus einer unter Druck stehenden Erdgasquelle. Partikelfilter:1 micron Edelstahl T-Filter Maximaler Probengasdruck (Einlass):ca. 200 bar Druck am Ausgang:0.0 – 1.0 bar (typischerweise 0.28 bar)
AF22e - Analityk dwutlenku siarki serii E SO2

AF22e - Analityk dwutlenku siarki serii E SO2

UV Fluorescence gas monitor offering excellent performances for the monitoring of SO2 in the range 0-10 ppm or 0-1 ppm. Option: H2S / TRS monitoring. Measured parameter :SO2 Technology:UV Fluorescence US-EPA Approval / QAL 1 Certification:Yes Measurement ranges :0-1 ppm or 0-10 ppm user-defined Measurement units:ppb, ppm, µg/m3 user-defined Lower Detectable Limit (2σ):< 0.4 ppb Noise (σ):< 0.2 ppb Zero drift:< 1 ppb / 24h Span drift:< 0.5% / 7 days Linearity:± 1%
FlowJam - Ciągłe wykrywanie przepływu materiału

FlowJam - Ciągłe wykrywanie przepływu materiału

Microwave sensor for contactless monitoring of material flow and detection of material blockage. The FlowJam is a processsecure device, since the microwave technology used can penetrate material coating on the sensor and reliably detect the material movement behind it. • detection of material blockage and material standstill • insensitive against material deposits • for any line diameter • compact (no separate electronics) • with ceramic mounting, usable up to 1,000 °C